Configuration
Technical Manual
89
V28 - 08/2019
Electronic safe lock
15.1.7.6
Configuring Bolt Open Time in Bank Mode
Submenu BLT OPN bank
Authorization: Master Code
Ex factory the Bolt Open Time in Bank Mode is set to 6 seconds.
When the lock is opened in Bank Mode, it will close automatically when the Bolt Open Time
has elapsed.
It is possible to prevent the lock from closing automatically either when a door contact is con-
nected or the bolt work is kept open..
1.
Select the submenu BLT OPN bank.
2.
Press the ENTER key.
ð
The current Bolt Open Time will be displayed (minutes:seconds).
3.
Use the LEFT or RIGHT arrow key to set the desired Bolt Open Time (setting from 00:06
to 99:00 minutes).
4.
Press the ENTER key.
5.
Select "YES" in the "SAVE?" dialog by using the LEFT or RIGHT arrow key.
6.
Press the ENTER key to confirm the setting.
15.1.7.7
Configuring Process Time Window in OTM
Submenu PROCTIM cit
Authorization: Master Code
Ex factory the Process Time Window is set to 2:30 minutes.
This function is used to define a time period in OTM (ICS or OTC) to enter an opening code af-
ter identification.
1.
Select the submenu PROCTIM cit.
2.
Press the ENTER key.
ð
The currently set time window will be displayed (minutes:seconds).
3.
Use the LEFT or RIGHT arrow key to set the desired time window (setting from 01:00 to
99:00 minutes).
4.
Press the ENTER key.
5.
Select "YES" in the "SAVE?" dialog by using the LEFT or RIGHT arrow key.
6.
Press the ENTER key to confirm the setting.