![Dormakaba Axessor CIT Technical Manual Download Page 42](http://html.mh-extra.com/html/dormakaba/axessor-cit/axessor-cit_technical-manual_2522971042.webp)
Functionality
Technical Manual
42
V28 - 08/2019
Electronic safe lock
User Code
Description
Result
User Codes 45 and
46
It is possible to define User
Codes 45 and 46 as Impulse
Code via AS284-USBW or
AS284-NETW.
It is possible to define the Im-
pulse Code for each output of
the lock or eBox via AS284-
USBW or AS284-NETW (max.
2 outputs).
When entering either User Code 45
or 46 an impuls is generated on the
respective output.
If this function is activated, it is not
possible to open the lock with the
User Codes 45 and 46.
User Code 47
It is possible to define the User
Code 47 as Time, Audit and
Battery Code via AS284-
USBW or AS284-NETW.
The User Code 47 has access to all
functions relating time, date,
weekly and holiday programs.
It is not possible to open the lock
with User Code 47.
If the User Code 47 is configured as
Audit or Battery Code via AS284-
USBW or AS284-NETW, the user
can either read the audit or reset
the battery message after the bat-
tery compartment had been
opened.
User Code 48
It is possible to define the User
Codes 48 and 49 via AS284-
USBW or AS284-NETW to de-
activate or activate the lock
opening.
When entering the User Code 48,
the lock does not open, lock dis-
abling is activated.
The lock rejects any opening code.
When entering the User Code 49,
lock enabling is activated.
User Code 49
11.7.2.4
Courier Code
There is only 1 Courier Code (Courier Code ID 90) which is provided for special staff from
Cash-In Transit services (CIT) responsible for filling or emptying secured containers without
any configured Time Delays.
Factory setting:
No code assigned
Functions:
Opening the lock, even in Dual Mode by bypassing a
Time Delay
Alteration of Courier Code
Courier Code func-
tion
Description
Result
"Courier does not
open but skips Time
Delay"
When entering the Courier
Code to open the lock, the
Time Delay will be skipped for
the next opening.
The Confirmation Window count-
down indicates the duration of this
condition.
The opening procedure must start
during countdown.
11.7.2.5
Duress Code
If the lock is connected to an external alarm system, it is possible for the operator to activate
a silent duress alarm which is imperceptible for the aggressor.
It depends on the current operating mode in which way a duress alarm is activated.
The Courier Code always opens the lock with a time delay.
This behavior is irrespective of configured time delays and also applies in case of a possible
threat.