Configuration
Technical Manual
104
V28 - 08/2019
Electronic safe lock
2.
Press the ENTER key.
ð
It is displayed when Time Lock Periods apply for OTM codes (ON) or do not apply
(OFF).
3.
Select either ON or OFF by using the LEFT or RIGHT arrow key.
4.
Press the ENTER key to confirm the setting.
5.
Select "YES" in the "SAVE?" dialog by using the LEFT or RIGHT arrow key.
6.
Press the ENTER key to confirm the setting.
15.1.9.16
Activating or deactivating NRTD for OTC
When the function NRTD is activated, it is not possible to switch from Bank Mode to OTC by
pressing the DEL key
Ex factory a Non Return Time Delay (NRTD) applies for OTC.
One Time Codes must be set to OFF if NRTD is not applied.
Example: The lock is used in Bank Mode with NRTD.
One Time Codes are used in special cases to open the lock.
Theses codes are required from the dispatcher.
It is only possible to configure 1 function at a time via AS284-USBW or AS284-NETW pro-
gramming software either Remote Disabling or cancel Non Return Time Delay (NRTD).
Both functions cannot be configured at the same time.
Authorization: Master Code
1.
Select the submenu NRTD cit.
2.
Press the ENTER key.
ð
The status message is displayed if NRTD is activated (ON) or deactivated (OFF).
3.
Select either ON or OFF by using the LEFT or RIGHT arrow key.
4.
Press the ENTER key to confirm the setting.
5.
Select "YES" in the "SAVE?" dialog by using the LEFT or RIGHT arrow key.
6.
Press the ENTER key to confirm the setting.
15.1.9.17
Displaying current Time
A set OTM is displayed with the message IDENTIF in the LCD of the input unit.
To indicate the current time on the display, the setting must be activated (ON).
Authorization: Master Code
1.
Select the submenu TIME cit.