![Dormakaba Axessor CIT Technical Manual Download Page 88](http://html.mh-extra.com/html/dormakaba/axessor-cit/axessor-cit_technical-manual_2522971088.webp)
Configuration
Technical Manual
88
V28 - 08/2019
Electronic safe lock
5.
Select "YES" in the "SAVE?" dialog by using the LEFT or RIGHT arrow key.
6.
Press the ENTER key to confirm the setting.
15.1.7.4
Configuring the Beeper Time Delay for Door Opening Alarm
Submenu D-ALARM
Authorization: Master Code
Factory setting for the Beeper Time Delay for Door Opening Alarm is OFF.
Factory setting for the Beeper Time Delay for Door Opening Alarm is 3 minutes.
Once the door is open, the lock will notify the user when the door opening time has elapsed.
1.
Select the submenu D-ALARM.
2.
Press the ENTER key.
ð
The currently set beeper Time Delay for Door Opening Alarm will be displayed (min-
utes:seconds).
3.
Use the LEFT or RIGHT arrow key to set the defined beeper Time Delay for Door Opening
Alarm (setting from 00:00 to 99.00 minutes).
4.
Press the ENTER key.
5.
Select "YES" in the "SAVE?" dialog by using the LEFT or RIGHT arrow key.
6.
Press the ENTER key to confirm the settings.
15.1.7.5
Configuring the window for a second code in Dual Mode
Submenu DUAL bank
Ex factory the opening window is set to 1 minute.
In Dual Mode a second opening code must be entered within a limited time period.
1.
Select the submenu DUAL bank.
2.
Press the ENTER key.
ð
The currently set time will be displayed (minutes:seconds).
3.
Use the LEFT or RIGHT arrow key to set the desired time to enter a second opening code
(setting from 00:15 to 02:30).
4.
Press the ENTER key.
5.
Press ENTER key.
6.
Select "YES" in the "SAVE?" dialog by using the LEFT or RIGHT arrow key.
7.
Press the ENTER key to confirm the setting.