Service program
12.1 Introduction
The service program is used by the installation
engineer or service and maintenance engineer for:
•
Displaying the water heater history
;
•
Displaying the error history
;
•
Displaying the water heater history
;
•
Display the selected water heater
;
•
Switching the pump on or off
;
•
Setting the service interval
;
•
Service mode
;
•
Setting legionella prevention
.
These sub-menus are briefly described in the
following paragraphs. If you are not generally familiar
with the use of the displays and menus, first read the
relevant chapter
(7 "The control panel")
.
Note
The notation convention for the service menu is
identical to that of the main menu
(11.2 "Notation
convention for menu-related instructions")
. The
difference is, you use
to bring up the service
program, instead of
which brings up the main
menu.
12.2 Setting the hysteresis
If the preset temperature (SET POINT) is higher than
the current water temperature, the water heater might
not
immediately start the operating cycle
(2.3 "Water
heater operating cycle")
. To prevent excessively
frequent switching on and off, there is a heating
margin. This margin is called the hysteresis. The
standard setting for this margin is 5°C. The operating
cycle starts when the water temperature drops to 5°C
below the SETPOINT and ends when the water
reaches 5°C above the SETPOINT.
Set the hysteresis as follows:
•
:
HYSTERESE UP
The figure shows an example
Set the hysteresis as follows
•
:
HYSTERESE DOWN
12.3 Displaying the error history
Display the error history as follows:
•
:
HISTORY OF ERRORS
The controller will display an overview of "Blocking
errors" and "Lock out errors". In both cases, note that
the controller reserves 15 lines for the last 15 error
messages. If there are fewer than 15 error messages,
an ellipsis (...) is displayed. The display first shows the
"Blocking errors". When
is pressed, the
"Lock out errors" are then displayed.
The figure shows an example of "Blocking errors". In
this case, the text
HISTORY OF ERRORS
is followed
by
(B)
.
The figure shows an example of "Lock out errors". In
this case, the text
HISTORY OF ERRORS
is followed
by
(L)
.
Note
For an overview of all errors and the possible
causes, please refer to the relevant
chapter
(13 "Errors")
.
SERVICE MENU
»HYSTERESE
^ HISTORY OF ERRORS
È APPLIANCE HISTORY
SELECT APPLIANCE
PUMP RELAY
SERVICE INTERVAL
SERVICE OPERATION
ANTI LEGIONELLA
HYSTERESE UP
»3ÉC
HISTORY OF ERRORS(B)
S04 SENSOR ERROR
F06 IONIZATION
È CO2 50 HZ ERROR
HISTORY OF ERRORS(L)
F02 FAN
F07 FLAME ERROR
È ...
Summary of Contents for DR-FC 120
Page 2: ......
Page 4: ......
Page 6: ...4 Instruction manual DR FC gis...
Page 10: ...Table of contents 8 Instruction manual DR FC...
Page 58: ...Shutting down 56 Instruction manual DR FC 10 gis...
Page 70: ...Service program 68 Instruction manual DR FC 12 is...
Page 84: ...Service interval 82 Instruction manual DR FC 14 is...
Page 90: ...Warranty 88 Instruction manual DR FC 16 s...
Page 93: ...Instruction manual DR FC 91 is...
Page 96: ...Appendices 94 Instruction manual DR FC 17 is...
Page 98: ...Instruction manual DR FC 96...