gis
The display shows the menu for the week program,
see the figure below. With the default setting, the
program switches on and off every day at 00:00 and
23:59 hours respectively, the water temperature is
65°C and the pump is switched on (
P
).
Example
As an example, we will set the switch-on time for
Sunday to 08:15 hours, and the matching switch-off
time to 12:45 hours. The water temperature will be set
to 75 °C and the pump will run continuously.
The following settings are entered one by one via the
menu: the switch-on time, the switch-off time, the
desired water temperature, and the mode of the
program-controlled pump.
11.7.1
Week program: setting the
switch-on time
1. Bring the cursor to
SU
Confirm with
.
The day indicated by
»
blinks.
2. Use and to set the desired day. In the example
this is
SU
(Sunday).
Confirm with
.
The cursor moves to the hour digits, which will
blink.
3. Use and to set the hours. In the example, this
is
08.
Confirm with
.
The cursor moves to the minute digits, which will
blink.
Note
Because the switch-off time can never be earlier
than the switch-on time, the switch-off time setting is
automatically adjusted with the switch-on time.
4. Use and to set the minutes. In the example,
this is
15
.
Confirm with
.
The cursor moves to the switch-off hour digits,
which will blink.
11.7.2
Week program: setting the
switch-off time
1. Use and to set the hours. In the example, this
is
12
.
Confirm with
.
The cursor moves to the minute digits, which will
blink.
2. Use and to set the minutes. In the example,
this is
45
.
Confirm with
.
The cursor moves to the desired water
temperature.
DAY TIME Tset
ON »SU
00:00 65ÉC P
OFF SU
23:59
ON MO
00:00 65ÉC P
OFF MO
23:59
ON TU
00:00 65ÉC P
OFF TU
23:59
ON WE
00:00 65ÉC P
OFF WE
23:59
ON TH
00:00 65ÉC P
OFF TH
23:59
ON FR
00:00 65ÉC P
OFF FR
23:59
ON SA
00:00 65ÉC P
OFF SA
23:59
INSERT
DELETE
START OPERATION
ON
»SU 00:00
OFF
SU 23:59
Tset 65ÉC
PUMP ON
SAVE
ON
SU»00:00
OFF
SU 00:59
Tset 65ÉC
PUMP ON
SAVE
ON
SU 08»00
OFF
SU 08:00
Tset 65ÉC
PUMP ON
SAVE
ON
SU 08:15
OFF
SU»08:15
Tset 65ÉC
PUMP ON
SAVE
ON
SU 08:15
OFF
SU 12»15
Tset 65ÉC
PUMP ON
SAVE
ON
SU 08:15
OFF
SU 12:45
Tset»65ÉC
PUMP ON
SAVE
Summary of Contents for DR-FC 120
Page 2: ......
Page 4: ......
Page 6: ...4 Instruction manual DR FC gis...
Page 10: ...Table of contents 8 Instruction manual DR FC...
Page 58: ...Shutting down 56 Instruction manual DR FC 10 gis...
Page 70: ...Service program 68 Instruction manual DR FC 12 is...
Page 84: ...Service interval 82 Instruction manual DR FC 14 is...
Page 90: ...Warranty 88 Instruction manual DR FC 16 s...
Page 93: ...Instruction manual DR FC 91 is...
Page 96: ...Appendices 94 Instruction manual DR FC 17 is...
Page 98: ...Instruction manual DR FC 96...