The pulse option can be selected to output a pulse for 1/16th of a second once the setpoint
is set. If the active high selection is made with the pulse selection, the output will go from
.6vdc to 5vdc for about 1/16th of a second, then return to .6vdc. Once the output has been
pulsed once, the output will not pulse the output again until the scale returns to within 1% of
the capacity of the scale. Selecting the active low will cause the opposite of the above to
be output.
24. Time and Date Output Format (t.d.O)
Option
Description
non
No date or time print out.
1
Print "MM/DD/YY" only.
2
Print "DD/MM/YY" only.
3
Print "HH:MM:SS AM/PM" only.
4
Print "HH:MM:SS HR" only.
5
Print "MM/DD/YY HH:MM:SS AM/PM."
6
Print "MM/DD/YY HH:MM:SS HR."
7
Print "DD/MM/YY HH:MM:SS AM/PM."
8
Print "DD/MM/YY HH:MM:SS HR."
Option 42 OPT 27 must be installed for the Time and Date feature to function. The Time
and Date Output Format is used to enable and select the printout format of the time and/or
date. When selected to something other than non, the selected format will be printed after
the selected print format (parameter 15) has been printed.
See Section 4 for instructions on setting the time and date.
Section 6 Parameter Setup
44