6-2
ENGINE
Working mode selector does
not work.
Blown fuse.
Replace fuse.
Working mode selector switch.
Replace switch failed.
Connector failed.
Replace connector.
Wiring harness damaged.
Repair or replace as required.
e-EPOS controller failed.
Repair or replace as required.
Problem
Cause
Remedy
Problem
Cause
Remedy
Starter does not operate.
Low battery power.
Charge battery.
Poor terminal contact.
Clean and tighten connections.
Starter switch failed.
Replace switch.
Starter relay failed.
Replace relay.
Starter controller failed.
Replace controller.
Wiring harness faulty.
Replace harness.
Battery relay failed.
Replace relay.
Blown fuse.
Replace fuse.
Starter engages, engine
does not start.
Fuel gelled in cold weather.
Replace fuel.
Fuel filters plugged.
Replace filters.
Water or dirt in fuel system.
Clean system and add new fuel.
Air in fuel system.
Purge air from system.
Engine stop control failed.
Contact your DOOSAN dealer.
Engine stop relay failed.
Replace relay.
Blown fuse.
Replace fuse.
Engine starts, runs only at
low speed or shuts down.
Engine oil viscosity incorrect.
Change oil.
Clogged or dirty fuel injectors.
Clean injectors.
Fuel filters plugged.
Replace filters.
Summary of Contents for DX700LC
Page 2: ......
Page 72: ...OP001120 Safety 1 66 ...
Page 142: ...OP001121 Operating Controls 2 70 ...
Page 188: ...OP001122 Operation 3 46 ...
Page 197: ...OP001123 4 9 Inspection Maintenance and Adjustment ...
Page 282: ...OP001123 Inspection Maintenance and Adjustment 4 94 ...
Page 298: ...OP000030 Troubleshooting 6 6 ...
Page 301: ...OP001125 7 3 Specification ...
Page 308: ...OP001125 Specification 7 10 ...
Page 314: ...950106 00012E Index 8 6 ...