DoorHan ECO FAST Installation And Operating Instructions Manual Download Page 3

3

Installation requirements

The vertical installation angles and tracks shall be fastened to the walls 

• 

securely, Their verticality should be verified with a level. 

The diagonals of the horizontal tracks shall be leveled(allowed devia-

• 

tion is +/-5mm).

If the floor surface is uneven, the vertical tracks shall be levelled hori-

• 

zontally by putting a wooden block under the vertical angle.

Assemble the units strictly in accordance with the instruction.

• 

The side end caps of the panels should be perfectly aligned gaps are 

• 

not permitted.

Spring tension adjustment shall be performed by moving the bottom 

• 

plug of the spring relatively the spring tensioner bracket 

(see page. 

29, рic. V)

.

Methods of fastening to the wall:

• 

a)  if  the  wall  material  is  (solid  brick,  solid  concrete,  metal  beam)the 

main supporting elements can be fastened directly to the wall.

b) if the wall material is not solid(hollow brick, hollow masonry blocks, 

weak concrete, wood, etc)it is necessary to install a steel frame around 

the perimeter of the opening. Before starting installation check that all 

hardware items correspond to the supplied specification and parts list.

Installation responsibility:

The manufacturer DoorHan does not handle direct control of installa-

• 

tion, maintenance and operation of the sectional door and shall be not 

held responsible for safety and quality of its installation;

The  content  of  the  directions  may  not  be  basis  for  any  complaints 

• 

against the manufacturer DoorHan;

The  company  performing  installation  of  the  sectional  door  shall  be 

• 

held responsible for the quality of installation;

The company DoorHan reserves the right to make alterations in the 

• 

instructions without notifying the customer.

OPERATION

The door should move up and down without difficulty.

• 

The door should be balanced.

• 

Open/close the door using the manual handle.

• 

Lock the door using special latch or mechanical lock.

• 

Do not grease parts of the door.

• 

Keep away children and animals from the operation area of the door 

• 

and do not restrict the door when opening/closing.

EMERGENCy CONDITIONS

Do not repair the door in case of failure. It is recommended to call the 

• 

technical support service;

After trigger off of the safety device make sure that nobody is injured. 

• 

Call for the technical support service;

If the door rises with difficulty, make sure, that all components of the 

• 

door  are  faultless  and  make  adjustments  after  that.  If  there  are  any 

damages, contact the technical support service.

TEChNICAL SUPPORT SERvICE

In case you encounter any difficulty, contact our support service on the fol-

lowing addresses:

а) [email protected],

b) product purchase address.

You can contact your dealer if you need any help in relation to the opera-

tion of the door. Related addresses and telephone numbers are stated in 

the contract. 

GENERAL INSTALLATION DIRECTIONS

Installation screw requirements

Installation crew requirements – 2 persons. Optimum instruction crew 

• 

should be made up of two persons. If the door to be installed will be 

electrically operated the crew should include a licensed electrician.

Average installation time is 3.5 hours.

• 

The instruction of the door to be carried out by Doorhan certified in-

• 

stallers Trained at Doorhan’s training centre

The crew shall be equipped with the proper tooling suitable for the in-

• 

struction (see page 20)

Do  not  install  on  the  door  the  parts,  which 

are not included in the door set.

Keep  children  away  from  the  installation  of 

the door. 

While mounting the electric operator follow 

the supplied installation instructions.

Before  installation  of  the  door,  make  sure, 

that  the  opening  is  prepared  according  to  sup-

plied technical data.

The opening of the door shall be free of any 

obstacles.

CONTENTS:

1. General installation instructions  .......................................................................  3

2. Door operation  ........................................................................................................  3

3. Emergency conditions  ..........................................................................................  3

4. Technical support service  ....................................................................................  3

5. Door installation  ......................................................................................................  22

These are instructions for the installation of RSD and ISD series ga-

rage and industrial sectional doors of the company DoorHan based on 

standard track configuration. 

The instructions contain important information on installation, op-

eration and maintenance of the door. 

Please, keep these instructions.

In case you encounter any difficulty when installing the door, it is 

recommended to contact the technical support service (see “Technical 

support service”).

ENGLISh

Summary of Contents for ECO FAST

Page 1: ...RSD01 ECO FAST Installations og brugsanvisningen for porten RSD01 ECO FAST Navodila za monta o in uporabo vrat RSD01 ECO FAST Installasjons og bruksanvisningen for porten RSD01 ECO FAST Installations...

Page 2: ...2 2 3 5 DoorHan 20 5 29 V DoorHan DoorHan DoorHan support doorhan com 1 2 2 2 3 2 4 2 5 22 DoorHan RSD01 Eco Fast...

Page 3: ...tions Do not repair the door in case of failure It is recommended to call the technical support service After trigger off of the safety device make sure that nobody is injured Call for the technical s...

Page 4: ...ce d assistance technique Lors de la mise en service du dispositif de s curit assurez vous qu il n y ait pas de bless s et contactez le service assistance technique Si l ouverture de la porte est diff...

Page 5: ...chtgever enige wijzigingen in deze gebruiksaanwijzing te brengen Gebruik van de poorten De poort moet ongestoord omhoog en omlaag gaan De poort moet juist gebalanceerd worden het mag niet spontaan om...

Page 6: ...delle porte deve essere eseguita con la mano vella installata Le porte si chiudono con la nottola speciale o una serratura mecca nica E proibito lubrificare i dettagli delle porte Durante l esercizio...

Page 7: ...s en la presente instrucci n sin avisar al cliente Explotaci n de la puerta La puerta debe levantarse y bajarse sin dificultades Es necesario balancear la puerta no debe levantarse y bajarse espont ne...

Page 8: ...ousopr ticodeport esemcausanemassumearesponsabili dade pela seguran a da sua montagem e pela qualidade desta ltima O conte do das presentes instru es n o pode servir de base para apresentar quaisquer...

Page 9: ...mik suoritta asennuksen Yrityksell DoorHan on oikeus tehd muutoksia t h n ohjeen ilman ilmoittamista siit tilaaja Porttien k ytt Portit piit nousta ja laskea ilman vaikeuksia Portit pit olla tasapain...

Page 10: ...r n vrat je nezbytn prov d t pouze s pomoc namon tovan rukojeti Vrata se zamykaj s pomoc speci ln z padky nebo mechanick ho z mku Je zak z no mazat jak mikoliv mazadly sou sti vrat V provozn m prostor...

Page 11: ...Dru ba DoorHan si pridr uje pravico na vnos sprememb v ta navodila brez predhodnega obvestila naro nika Uporaba vrat Vrata se morajo dvigati in spu ati brez te av Vrata je potrebno uravnote iti ne sme...

Page 12: ...denne vej ledning uden forudg ende varsel Brugen af porten Porten skal h ves og s nkes uhindret Porten skal justeres den m ikke h ves og s nke spontant Porten m kun lukkes og bnes ved hj lp af det in...

Page 13: ...rten skall justeras den skall inte s nkas eller h jas spontant Porten skall endast st ngas och ppnas med hj lp av det installerade handtaget Porten skall l sas med en s rskild sp rr eller ett mekanisk...

Page 14: ...for monteringen Produsenten DoorHan har ingen direkte kontroll over montering ved likehold og bruk av porten og er derfor ikke ansvarlig for monterin gens sikkerhet og kvalitet Veiledningens innhold k...

Page 15: ...si za pomoc specjalnego zatrzasku lub zamka me chanicznego Zakazuje si smarowania element w bram W obszarze pracy bramy w czasie jej eksploatacji nie powinny si znajdowa adne elementy zwierz ta lub z...

Page 16: ...voluntar nchiderea i deschiderea por ilor trebuie realizat cu ajutorul m ne rului instalat Por ile se nchid cu ajutorul clichetului special sau lac tului mecanic Se interzice gresarea pieselor por ilo...

Page 17: ...17 29 V DoorHan DoorHan DoorHan support doorhan com 2 3 5 DoorHan 20 5 1 17 2 17 3 17 4 17 5 22 DoorHan RSD ISD...

Page 18: ...Tor selbst zu repa rieren Reparaturen darf nur von einer sachkundigen Person durch gef hrt werden Es wird empfohlen sich an unsere Kundendienst zu wenden Im Falle des Absicherungsger tsausl sens sich...

Page 19: ...19 3 5 20 5mm 29 V support doorhan com 1 19 2 19 3 19 4 19 5 22 DoorHan RSD ISD...

Page 20: ...20 16 10 13 11 14 12 15 4 19 mm f i b g l c h m d n e k S10 S12 S10 S12 5 m 0 5 m 1 4 7 2 5 8 3 6 9...

Page 21: ...21 19 22 17 20 23 18 21 24 25 26 6 3x38 3 5x13 M10x35 6 3x25 M8x16 8x100 6 3x16 1 4x3 4 A D G H B C F E...

Page 22: ...22 2 2 1a 2 2a 2b 2c 2d 1 1 min 120 mm min 120 mm h 100 mm 1 2 B1 B2 2 2c 2d 2b 2b 2 1 D D D D 2 _ a 2 1 2 3 3 3 3 3 7 8 9 9 9 18 1 2 8 7 18...

Page 23: ...23 3 3 1b 3 2b 3c 3 3b 3a G 3c 3a 3 _ b B 5 5 6 10 17 17 20 20 25 25 6 5 10...

Page 24: ...24 4 4 1 5 1 5 2 5 3 5 _ a 1 1 2 2 5 10 mm A E 25 mm 25 mm 40 45 mm 40 45 mm 5 5 5 5...

Page 25: ...25 6 6 1 6 2 10 mm 10 mm 7 8 7 1 8 1 A A E E 8 1 C 16 10 10 5 6 20 25...

Page 26: ...26 9 9 1a 9 2a 9 3a 9 4a B 9 _ a 9b 9c C 9b 9c C C 5 12 5 5 4 11 4 4 4 5 5 12 11 11...

Page 27: ...27 A B 5mm A B 10 _ b 10c 10 _ a 10 1a 10 2a 10 1b 10 4a 10 3b 10c 10 3a 10 2b 10 A A E E B B H H 4 4 15 4 4 15 21 21 15 6 19 20 20 20 20 6 6 19...

Page 28: ...28 13 11b 11b 11 _ a 11 _ a 12 12 _ 13b 13a 13c 12 1 13a 13c 11 2a 12 2 13b 11 11b 11 1 a 12 13 B B D D D 3 2 1 7 8 8 8 18 1 2 3 7 7 8 9 9 18 22 22 22 23 23 23 23 23...

Page 29: ...29 I IV II V VI III F 10 13 13 14 12 3 9 14 10 14 13 14...

Page 30: ...30 14 15 15 2 15 1 15 3 14 1 14 2 12 mm 4 mm 15 mm D 3 2 5 26 24 26...

Page 31: ...31 4 mm 19 mm 198 mm 40 mm 5 5 mm 15 mm 16 16 1a 16 1b 16 2a 16 3a 16 _ b 16 _ a 16 2b 17 18 19 20 21 24 22 25 23 26 D...

Page 32: ...32 www doorhan com...

Reviews: