WSO 10, 15, and 20
7
CAUTION!
• Combustible materials such as buffing lint, paper, wood, aluminum or steel dust, weld fume,
or flammable solvents represent fire or explosion hazards.
• Use special care when selecting and operating all collection equipment when combustible
materials are present to protect workers and property from damage due to fire and/or
explosion.
• Consult and comply with all national and local codes relating to fire or explosion, and all
other appropriate codes when determining the location and operation of mist collection
equipment.
• Donaldson equipment is not equipped with fire extinguishing or explosion protection systems.
Site Selection, Ceiling-Mounted Units:
1. The unit can be suspended or hung from
overhead supports. The supports must be
adequate to carry the live load of the unit and
installation performed to reduce sway or
vibration to the unit. The dry unit weight is
shown on the specification control drawing
shipped with the unit.
2. The live load will include the weight of all
ancillary hardware attached to the mist
collector, as well as the weight of the mist-
laden, wet filters. Consult the coolant MSDS for
the specific gravity of the coolant to estimate
the weight of the mist-laden, wet filters.
3. Provide clearance from heat sources and
interference with utilities when selecting the
location for suspended units.
CAUTION!
Ensure weight of oil-laden unit plus weight
of required materials and equipment will
be adequately supported. Failure to
comply may result in personal injury
and/or property damage.
Unit Location
1. When hazardous conditions or materials are
present, consult with local authorities for the
proper location of the collector.
2. Foundation or overhead support must be sized
to accommodate the entire weight of the unit,
plus the weight of the collected material, piping,
and ductwork.
CAUTION!
Ensure weight of oil-laden unit plus weight
of required materials and equipment will
be adequately supported. Failure to
comply may result in personal injury
and/or property damage.
CAUTION!
Donaldson equipment is not designed to
support site-installed ducts,
interconnecting piping, or electrical
services. All ducts, piping, or electrical
services supplied by others must be
adequately supported to prevent severe
personal injury and/or property damage.
Summary of Contents for WSO 10
Page 1: ...IOM AK0300601 Revision 2...
Page 9: ...WSO 10 15 and 20 9 This Page Intentionally Left Blank...
Page 15: ...WSO 10 15 and 20 15 This Page Intentionally Left Blank...
Page 24: ......
Page 27: ...WSO 10 15 and 20 27 This Page Intentionally Left Blank...
Page 35: ...WSO 10 15 and 20 35 e t a D d e m r o f r e P e c i v r e S s e t o N Service Notes...
Page 37: ...This Page Intentionally Left Blank...
Page 38: ...This Page Intentionally Left Blank...
Page 39: ......