Inlet Hopper with Flex-Duct Installation
This option is available for ceiling mounted units or
units on stands. Included components are a 6-in
integrated collar on the inlet hopper, 10-ft flexible
duct, and two 6-in hose clamps.
1. Slip flex-duct over inlet collar on collector and
install hose clamp over flex-hose and collar and
securely fasten.
2. Trim flex-duct to the desired length and fasten
to machine center or inlet hood with remaining
hose clamp.
Note:
Do not allow flexible duct to create a
fluid trap. See Flex-Duct Positioning
illustration in General Installation
section.
3. Install drain / P-trap. See P-Trap Installation
section.
sealant
inlet hopper
hose clamp
flex-duct
hose clamp
filter cabinet
P-trap drain
Inlet Hopper with Flex-Duct, WSO 15 shown
sealant
side inlet
hopper
hose
clamp
flex-
duct
filter
cabinet
hose
clamp
P-trap
drain
Side Inlet Hopper with Flex-Duct, WSO 15 shown