Donaldson Company, Inc.
34
Troubleshooting, continued
Problem
Probable Cause
Remedy
Insufficient airflow
Blower rotation backwards
Proper blower rotation is clockwise when
looking down at the blower motor. See
Preliminary Start-Up Check section.
Access doors open or not
closed tight
Check that all access doors are in place and
secured.
Blower exhaust area restricted Check blower exhaust area for obstructions.
Remove materials or debris.
First-Stage filter plugged
Remove and clean or replace.
Primary filter needs
replacement
Remove and replace using genuine Donaldson
replacement filter. See Primary Filter Replacement
section.
Plugged HEPA filter
Remove and replace. See HEPA Filter
Replacement section.
Insufficient hopper
discharge
Plugged hopper screen
Remove and clean hopper screen.
Plugged P-trap
Clean P-trap. See P-Trap Service section.
Liquid leaking from
collector door
Plugged P-trap
Clean P-trap. See P-Trap Service section.
Plugged or full drain
collection container
Remove and clean or empty the drain collection
container.