OPERATING WITH LAGO FB OT+ REMOTE CONTROL (OPTIONAL)
A remote control (
LAGO FB OT+
) can optionally be supplied together with
BioClass TR
boiler. This
remote control can be used to fully operate the boiler from anywhere in the room in which it is
installed. The
LAGO FB OT+
remote control regulates the parameters of heating circuit and the
domestic hot water production.
This remote control allows the hours of comfort to be programmed for heating circuit, regulating the
installation to the particular requirements of the building by measuring the room temperature and
consequently adapting the installation temperature. The remote control can also be used to regulate
the hot water and heating temperatures set point at any time, and for viewing the different boiler
operation parameters. It also warns of any functioning anomalies affecting the boiler.
The
LAGO FB OT+
remote control may optionally be connected to an outdoor temperature sensor, for
measuring the temperature around the building. With this option installed, the remote control can
adjust the building comfort level according to the weather conditions, optimising fuel consumption
and heating comfort in the building.
The
LAGO FB OT+
remote control takes over the control of the boiler when it is connected. The
different selectable temperatures boiler of the boiler must be set at the remote control. It is easy to
install, requiring only 2 wires for communication between the boiler and the
LAGO FB OT+
control, by
connecting the two wires on terminal strip
J5
(see
“Electrical Connection Diagram”)
. For a correct
installation and functioning, read carefully the instructions within the remote control.
The following sections contain a general explanation of the different operating modes and options of
LAGO FB OT+
remote control.
Operation of the heating circuit
The maximum temperature for heating circuit, the operating period of time and the desired room
temperature can be set at remote control.
LAGO FB OT+
remote control will calculate the boiler
temperature required at each particular time, depending on the temperature of the room and it will
activate or deactivate the heating demand depending on the heating times and room
temperatures programmed.
DHW service function
When
BioClass TR
boiler is installed together with a DHW tank the desired DHW temperature and
the desired periods of time for DHW service must to be set at
LAGO FB OT+
remote control.
LAGO
FB OT+
remote control regulates the DHW tank temperature and enables or disables the DHW
service according to the time periods scheduled.