55
BIOCLASS iC DX
17.7
Room thermostat connection
The boiler has a terminal strip
J6
for connecting a room thermostat or a room chrono-thermostat (
TA
1
,
see
"Connection Diagram"
) that allows to switch on and off the heating circuit demand according to
the actual room temperature. For correct connection and configuration, carefully read the instructions
in the section "Installing a room probe or thermostat".
Installing a room thermostat will optimise the installation's performance, adapting the heating to
building requirements and obtaining enhanced comfort. Also, if the thermostat allows the hours of
functioning to be programmed (chronothermostat), it can adapt the heating system to the hours of use
of the installation.
17.8
Connecting the room sensor
The boiler has a
J6
terminal strip, prepared for the connection of a room sensor (
TA
1
, see
"Connection
Diagrams"
), which will make it possible to manage the heating service of the direct boiler circuit (
BC
)
depending on the inside temperature of the house. For correct connection and configuration, carefully
read the instructions in the
"Installing a room sensor or thermostat"
section..
The installation of a room sensor will optimise the operation of the heating installation, adapting the
operation of the boiler to the needs of the home and improving comfort levels. The electronic control
will modulate the boiler temperature setpoints according to the ambient conditions read by the sensor,
optimising fuel savings and increasing the efficiency of the installation.
In turn, when there is a room sensor connected, the boiler's digital display will allow the programming
of the operating hours of the corresponding circuit
(see "Configuration Menu")
, so the heating system
can be adapted to the hours of use of the installation.