23
BIOCLASS iC DX
5.3
Boiler temperature set point selection
Boiler temperature set point selection is made by the tactile selector shown in the picture. Press “
+
”
and “
-
“ buttons to increase or decrease the set point desired. Few seconds after the desired set point
temperature is adjusted the display returns to main position. The range of values for boiler temperature
set point is OFF, 65 - 80 ºC.
It is also possible to set boiler temperature set point browsing through the
“User Menu”
by pressing
MENU
button. When parameter
“Boiler set point temperature”
is displayed, the boiler temperature set
point is set by pressing “
+
” and “
-
“ buttons.
When the
"OTC operating mode"
is activated by means of
P.10
parameter of
“Technical Menu”
and
the K-factor is set for the heating circuit of the boiler heating Zone 1 (parameter
P.45
of the "Technical"
menu), the boiler temperature set point is calculated depending on the K-factor selected. The boiler
temperature set point parameter only allows to set between activating ("
ON
") or deactivating ("
OFF
")
the heating service of said Zone.
It is possible to disable the heating service of the boiler (
Summer
mode) by setting to "
OFF
" the boiler
temperature set point by pressing “
-
“symbol for heating
(18)
.
5.4
DHW SET temperature selection
DHW SET temperature selection is made through the touch buttom shown in the picture. In order to
select the desired operation mode touch "+" o "-" symbols to surf through the different modes. Once
the mode is selected, in few seconds the screen will return to the repose situation. There are three
different DHW SET modes:
•
OFF: DHW function disabled.
•
ECO: Reduced comsuption DHW set.
•
PLUS: Maximum DHW production set.