8
Wireless room thermostat DK LOGIC 200
8. Receiver encoding
9. Interferences - communication error
A transmitter and receiver, which can be found in a single original box, have been
pre-set in the factory to use thus their encoding is not necessary.
If needed, the encoding steps described below must be followed:
Radio wave interferences may occur sporadically,
which can lead to a lack of communication
between the receiver and the transmitter. If this
happens, a red INTERFERENCES diode starts to
blink on a receiver and an Err1 message will be
displayed on the transmitter screen.
To restore communication follow the steps
described in the encoding process - see point
8
Receiver encoding.
1.
Press and hold for 5 sec. the FUNCTIONS button - the memory will reset -
a blue and red diodes will lit at the same time. Once the memory is cleared, a
red diode INTERFERENCES will flash.
2.
Press and hold for 1.5 sec. the FUNCTIONS button - the receiver will go to
a standby mode waiting for a code to be introduced - a blue and red diodes
will be flashing alternately.
3.
At that time, a TEST function must be called on the DK LOGIC 200
transmitter. A code will be directed to a receiver: two diodes blue and red will
blink twice at the same time.
4.
Next, a short communication test will be made - the RE1 relay will be
connected twice and an orange diode will be lit.
5.
The transmitter and receiver set has been properly configured.