7
Wireless room thermostat DK LOGIC 200
7. Installation and connection of the receiver to electrical
system
1.
Open the front part of the receiver housing.
2.
Using two screws and dowels attach the receiver to the wall.
3.
Turn off the voltage on a wire feeding the receiver.
4.
Connect the cables between a boiler or a programmer and a RE1 clamp in the
receiver (Fig.4).
5.
Connect the feeder cable with the appropriate clamps in the receiver (Fig.4):
-
a blue wire must be connected to the N clamp (“neutral”)
-
a brown wire must be connected to the L clamp (“phase”)
6.
Close the front part of the receiver housing.
7.
Turn the power on - a green diode POWER SUPPLY should lit on the receiver,
informing on the correct connection.
Note:
As the radio interferences are possible, it is recommended to
install the receiver at least 0.5m from large metal objects and
electrical quads
!
Fig. 4 Diagram of the receiver connections to the boiler/programmer and to
the electrical system
N L
RE1
RE1
~ 230 V, 50Hz
Boiler or
programmer
POWER SUPPLY
INTERFERENCES