Document XLDS Guide – Section Four A
Revised September 30, 2019
44
SECTION FOUR A: RDC REPAIR / MAINTENANCE / OVERHAUL
Figure 79
5. Carefully check manifold assembly, for signs
of damage, especially around the hose.
Figure 80 ICS Manifold Interface Hose
6. Clean manifold assembly, in accordance with
XLDS cleaning procedure.
7. Install new O-rings on port plugs or hoses,
3/8”-24 small bore (inflator hoses), use a -
010 O-ring. The center hose, helmet/full face
mask hose and the O-ring on the fitting that
screws into the ICS uses a -013 O-ring. Figure
81 and 82.
8. Port plugs are torqued to 15 in. pounds, LP
inflator hoses are 40 in. pounds, helmet/full
face mask hoses are 40 in. pounds, and the
fitting that screws into the ICS is 50 in. pounds.
Figure 81 (ICS Manifold Complete / Full Face
Mask Configuration)
Preliminary
After the entire ICS has been assembled, the ICS
needs to be tested for proper intermediate
pressure, and to ensure there are no leaks. Then
attach the ICS attached to the RDC console in the
normal configuration, so that it can be checked