© Copyright 2003-2019 Dive Lab® Inc. All rights reserved.
This Guide is made available for the express use of owners and users of the Dive Lab XLDS systems.
This information is subject to periodic updates and changes. Always check the Dive Lab web site for the latest versions.
Document XLDS Guide – Section Four A
Revised September 30, 2019
18
SECTION FOUR A: RDC REPAIR / MAINTENANCE / OVERHAUL
Preliminary
Ensure all high-pressure gas supplies have been
disconnected, and all pressure has been vented.
Open each diver circuit pneumofathometer valve,
to ensure the system is vented, then open each
umbilical supply valve. Ensure the work area and
all tools are clean.
The two and three diver RDC units are
disassembled and reassembled in the same
manner, therefore, this procedure will work for
both with only minor variation. It is strongly
recommended that you take pictures of pneumo
hose routing.
Tools and Components Needed
3/8” Open End Wrench
9/16” Open End Wrench
1/2” Open End Wrench
Torque Wrench 0-250 inch lbs.
3/8” Socket short
7/16 Socket
9/16 Socket
1/2” Socket
Christo Lube
Overhaul Kit PN# 1XL8RK
Brass Pick Set
Needle Nose Pliers
Thread Locker Compound-Medium Strength
1. Loosen and remove the hose fittings on Green,
Red and Yellow divers’ peumofathometer
valves (11).
Figure 17
2. Loosen and remove all the 7/16” lock nuts,
from each of the clamp blocks (21), then
remove the blocks and rubber strips. There
are 8 blocks on the three diver, and 5 blocks
on the two diver consoles.
Figure 18
3. Lift the two or three diver manifold assembly
from the box, as a whole. Place the manifold
on a clean flat work table.
Figure 19
4. Using the 1/2” wrench, loosen then remove
the valve handle retaining nut (12), from each
valve being disassembled, then remove the
lock washer (13) and handle (11).
NOTICE
Removing the entire manifold system from the
foundation plate (1), allows easier access to the
valves. Removing the entire manifold system,
is very quick and easy.