GB
22
GLOBE - IP1839
Output
Value
Description
1 +
0 -
24 V= / 0,3 A (nominal)
24 V= / 0,5 A (peak)
Accessories power supply.
External accessories power supply output.
0
14
24 V= / 30 W max.
Flashing light (LAMPH).
It is activated both on opening and on closing.
24 V= / 25 W
Courtesy light.
It is activated for 3 minutes on every opening and closing command.
BAT
Battery operation.
An optional battery kit is available (BATK1). With power supply
on, the batteries are kept charged. Without power supply, the panel is powered by the
batteries until power returns or until battery power falls below the safety threshold. In
this latter case, the control panel goes off.
Attention: to allow recharging, the batteries kit must always be connected to the control
panel. Periodically, verify the battery efficiency.
Note: the operating temperature of the rechargeable batteries is +5°C/+40°C
approximately. To ensure proper battery operation rooms should be air-conditioned.
0
15
24 V= / 1,2 A max
Electric lock.
It is avtivated at each opening command given from closed door.
0
15
8,2 Ω / 5 W
12 V / 15 W
Electric lock.
With a 12 V electric lock, connect the 8,2 Ω / 5 W resistor. It is activated
at each opening command given from closed door.
1
13
24 V= / 3 W
Open door light (analogic output).
Light comes on and only goes off when door is
closed.
4.2 Output and accessories
71R
Control
Function
Description
1
5
N.O. STEP-BY-STEP
With DIP1=OFF the closure of the contact activates the sequence: open-
stop-close-open.
Note: if automatic closing is enabled, the STOP is not permanent but at a
time that is set by TC.
OPEN WITH
AUTOMATIC CLOSING
With DIP1=ON and the automatic closure on, the closure of the contact
activates an opening operation.
OPEN WITHOUT
AUTOMATIC CLOSING
With DIP1=ON and TC=MAX, the closure of the contact activates an ope
-
ning operation.
With the automation idle, the closure of the contact performs the operation
opposite to that prior to the stop.
1
8
N.C.
REVERSAL
SAFETY CONTACT
The closing of the contact during the closure manoeuvre causes the move-
ment to invert (re-opening).
1
9
N.C.
STOP
The opening of the contact causes the movement to stop and the automatic
closure to be disabled.
Resetting the command, the door remains still until a 1-5 command or a
radio command is received.
AUX
The control panel has one space for coupling board, type radio receivers,
magnetic loops etc.
The coupling board working mode is selected by DIP1.
Warning: the plug-in cards must be inserted and removed with the power
supply disconnected.
4.1 Controls
Summary of Contents for GLOBE IP1839
Page 4: ...4 GLOBE IP1839 Fig 5a Fig 5b Fig 5c Y K 3000 GLOBEGF GLOBEGA Fig 5e Fig 5d E H Fig 5f...
Page 5: ...5 GLOBE IP1839 30 10 100 M 45 Fig 6 min 680 30...
Page 6: ...6 GLOBE IP1839 min 900 GLOBEC 30 Fig 7 30 min 20 max 210 GLOBEC...
Page 7: ...7 GLOBE IP1839 DOOR TYPE YEAR OF MANU FACTUR E VOL TAGE SUPPL Y SERIA L NUMB ER Fig 8...
Page 8: ...8 GLOBE IP1839 GLOBESI 30 8 75 42 220 30 8 75 42 220 Fig 9a Fig 9b Fig 9c...