GB
19
GLOBE - IP1839
1. TECHNICAL DETAILS
GLOBE7
GLOBE7J
GLOBE10
GLOBE10J
Power supply
230 V~ / 50-60 Hz
120 V~ / 50-60Hz
230 V~ / 50-60 Hz
120 V~ / 50-60Hz
Absorption
0,7 A
1,4 A
1,2 A
2,4 A
Fuse F1
F1,6A
F3,15A
F1,6A
F3,15A
Thrust
500 N
500 N
900 N
900 N
Max stroke
2500 mm
2500 mm
2500 mm
2500 mm
Max load
7 m²
7 m²
10 m²
10 m²
Opening speed
0,15 m/s (chain)
0,18 m/s (belt)
0,15 m/s (chain)
0,18 m/s (belt)
0,15 m/s (chain)
0,18 m/s (belt)
0,15 m/s (chain)
0,18 m/s (belt)
Closing speed
0,10 m/s (chain)
0,12 m/s (belt)
0,10 m/s (chain)
0,12 m/s (belt)
0,10 m/s (chain)
0,12 m/s (belt)
0,10 m/s (chain)
0,12 m/s (belt)
Service class
3 - FREQUENT
3 - FREQUENT
3 - FREQUENT
3 - FREQUENT
Intermittence
S2 = 30 min
S3= 50%
S2 = 30 min
S3= 50%
S2 = 30 min
S3= 50%
S2 = 30 min
S3= 50%
Temperature
-20° C / +55° C
-20° C / +55° C
-20° C / +55° C
-20°C / +55°C
Degree of protection
IP10
IP10
IP10
IP10
Control panel
70R
70R
71R
71R
2. REFERENCE TO ILLUSTRATIONS
The given operating and performance features can only be
guaranteed with the use of DITEC accessories and safety
devices.
2.1 Standard installation references
(fig. 1)
[1] Radio
[2] Drive unit
[3] Retention bracket
[4] Slide
[5] Release cord
[6] Guide
[7] Guide coupling
[8] Transmission
[9] Photocells
[10] Sensitive edge
[11] Connect the power supply to an omnipolar switch with
contact opening distance of at least 3 mm (not supplied)
or by means of power plug.
Connection to supply mains must be carried out in an
independent raceway separate from control connections
and safety device connections.
2.2 Accessories
BATK1
Battery kit
GLOBEC
Adapter for up and over doors with counterweights
ASB1
External release kit with cord and lock
ASB2
Cord release device
GLOBEL
Extension set for chain
GLOBELV
Extension set for belt (for steel guide only)
GLOBEFM
Additional close stop
GLOBESI
Intermediate support
GLOBEGF
Iron track
GLOBEGA
Aluminium track
3. INSTALLATION
3.1 Chain type GLOBE assembly (fig. 4)
- Extend the chain.
- Fit the coupling [1] as far as the guide stop. Fit the guide
[2] as far as the stop. Fit the coupling [3] as far as the guide
stop [2].
- Superimpose the guide [4] on the coupling [3], correctly fit
the transmission in the guide [4]: lift the guide as shown in
the detail to permit fitting the transmission.
- Move the coupling [3] towards the transmission as far as
the guide stop [4].
Note: the guides must be fitted in a specific direction (see stops
[x] shown in figure).
3.2 Belt type GLOBE assembly (fig.5)
- (fig. 5a) Fit the belt to the transmission and slide.
- (fig. 5b) Fit the belt stop as shown in the illustration.
- (fig. 5c) Fasten the two ends of the belt to the release pin
by means of the couplings keeping to the pin direction
shown in the illustration.
- (fig. 5d) Fit the drive pin (belt - transmission - slide) in the
guide.
- (fig. 5e) Pass the belt around the pulley and secure by
means of the pin [Y]. Fit the guide as shown in fig. 3, lock
in the drive unit as far as the stop and tighten screw [K].
- (fig. 5f) Push the transmission towards the outside of the
guide and fasten the retention bracket to the wall.
3.3 Chain or belt tensioning (fig.6)
- Correct tensioning is achieved by leaving 1÷2 mm between
the spring retainer [E] and stop [H] to enable the spring [E]
to work in the best possible way.
Attention: over-tightening could affect proper operation of the
automatic system.
E
H
1÷2
Summary of Contents for GLOBE IP1839
Page 4: ...4 GLOBE IP1839 Fig 5a Fig 5b Fig 5c Y K 3000 GLOBEGF GLOBEGA Fig 5e Fig 5d E H Fig 5f...
Page 5: ...5 GLOBE IP1839 30 10 100 M 45 Fig 6 min 680 30...
Page 6: ...6 GLOBE IP1839 min 900 GLOBEC 30 Fig 7 30 min 20 max 210 GLOBEC...
Page 7: ...7 GLOBE IP1839 DOOR TYPE YEAR OF MANU FACTUR E VOL TAGE SUPPL Y SERIA L NUMB ER Fig 8...