B-35
Procedures to connect the power lines of the uninterruptible power supply unit to the machine
(Continued)
Step No.
Procedure
3
Connect the power lines of the uninterruptible power supply unit to the corresponding
terminals on the terminal block (TB1).
・
Make sure to connect each line to its terminal correctly referring to the following figure.
Terminal block (TB1)
(Terminals for connection)
AC Input LINE side (J901)
: No. 1
AC Input NEUTRAL side (J901)
: No. 2
AC Output LINE side (J902)
: No. 3
AC Output NEUTRAL side (J902)
: No. 4
4
Connect the signal line (J105) of the uninterruptible power supply unit to its connector on
the panel at the bottom section of the control box.
Connector panel
[Bottom part as viewed from below]
5
Turn ON the power circuit breaker and the POWER switch of the uninterruptible power
supply unit, referring to the Instruction Manual of the UPS.
Continued in the next section.