background image

* Des idées en action.

Operating instructions

GWS 20-180
GWS 20-230
GWS 24-180 H
GWS 24-230 H
PROFESSIONAL

1 609 929 F75.book  Seite 1  Dienstag, 9. März 2004  9:19 09

Summary of Contents for GWS 20-180 Professional

Page 1: ... Des idées en action Operating instructions GWS 20 180 GWS 20 230 GWS 24 180 H GWS 24 230 H PROFESSIONAL ...

Page 2: ...3 2 605 510 173 2 605 510 174 1 600 793 007 1 605 510 179 1 605 510 180 Ø 180 mm Ø 230 mm Ø 180 mm Ø 230 mm Ø 180 mm Ø 230 mm 16 24 36 60 24 36 60 METAL 1 607 000 247 1 605 510 181 1 605 703 099 1 608 600 231 1 608 600 232 1 608 600 233 1 608 600 234 1 608 600 239 1 608 600 240 1 608 600 241 1 603 340 040 1 607 950 004 0 601 999 018 1 605 438 034 ...

Page 3: ...3 1 609 929 F75 04 03 ...

Page 4: ...4 5 1 609 929 F75 04 03 25 24 12 11 9 1 9 10 12 3 23 20 21 22 2 5 11 18 18 15 9 16 11 19 6 8 7 13 14 4 17 GWS 24 180 H GWS 24 230 H PROFESSIONAL 1 609 929 F75 U4 5 Seite 4 Dienstag 9 März 2004 9 20 09 ...

Page 5: ...power tool on A wrench or a key left attached to a rotating part of the power tool may re sult in personal injury e Do not overreach Keep proper footing and bal ance at all times This enables better control of the power tool in unexpected situations f Dress properly Do not wear loose clothing or jewellery Keep your hair clothing and gloves away from moving parts Loose clothes jewellery or long hai...

Page 6: ...ing cutting disc 11 Clamping nut 12 quick clamping nut 13 Clamping screw 14 Coded projection 15 Guard grinding cup 16 Grinding cup 17 Two pin spanner for clamping nut 18 Hand guard 19 Spacer discs 20 Rubber sanding plate 21 Sanding sheet 22 Round nut 23 Cup brush 24 Diamond cutting disc 25 Cutting guide with dust extraction protection guard 26 Cutting grinder stand Not all of the accessories illus...

Page 7: ...e must be mounted Hold the power tool only by the insulated gripping surfaces when performing an op eration where the cutting tool may run into hidden wiring or its own cord Contact with a live wire will make exposed metal parts of the tool live and shock the op erator Use appropriate detectors to determine if utility lines are hidden in the work area or call the local utility company for assist a...

Page 8: ...fits the machine type can be mounted Loosen the clamping screw 13 if necessary Place the protection guard 6 with coded projec tion 14 into the coded groove on the spindle col lar of the machine head and rotate to the required position working position The closed side of the protection guard 6 must always point to the operator Tighten clamping screw 13 Protection Guard with Quick Clamp The protecti...

Page 9: ...mounting the grinding tool and be fore switching on check that the grind ing tool is correctly mounted and that it can turn freely Flap Disc Depending on the application remove the protec tion guard 6 and mount the hand guard 18 Place the special mounting flange 9 accessory Order No 2 605 703 028 and the flap disc on the grinder spindle 5 Screw on the clamping nut 11 and tighten with the two pin s...

Page 10: ...st at least match the values given in the table Therefore always observe the permissible rotational circumferential speed on the label of the grinding tool Observe correct mains voltage The voltage of the power source must agree with the voltage specified on the nameplate of the machine Equipment marked with 230 V can also be con nected to 220 V Switching On and Off To start the machine press the ...

Page 11: ... The direction in which the cutting is per formed is important The machine must always work in an up grinding motion Therefore never move the machine in the other direction Otherwise the dan ger exists of it being pushed uncon trolled out of the cut Grinder Stand With the grinder stand 26 accessory work pieces can be cut at angles of 0 to 45 at the same lengths The safety notes and operating instr...

Page 12: ...ug For safe and proper working always keep the machine and the ventilation slots clean In extreme working conditions conductive dust can accumulate in the interior of the machine when working with metal The protective insulation of the machine can be degraded The use of a stationary extrac tion system is recommended in such cases as well as frequently blowing out the venti lation slots and install...

Page 13: ...wer Tool Division Motor Industries Co Ltd P B No 3000 Audugodi Hosur Road Bangalore 560 030 Ph 91 0 80 22 99 28 66 22 99 95 15 1 609 929 F75 04 03 O 16 Printed in India Imprimé en Inde Chlor Des idées en action ...

Reviews: