A-3
Machine specifications (Continued)
(for spindle coolant use)
Water used
If the chlorine, iron, copper or sodium content or electrical
conductivity is high, mechanical parts corrosion or hose clogging
may be caused.
Pressure
0.2 to 0.3 MPa
Flow rate
2 L/min or higher
Water
(Continued)
Water
temperature
20 to 25
°
C (the maximum permissible hourly temperature
variation is 2
°
C)
Displacement
4 to 6 m
3
/min
(at the duct hose connection port of the machine main body
when the static pressure is as below indicated)
Exhaust
Static pressure
0.4 kPa
(at the duct hose connection port of the machine main body)
Machine
dimensions
Main body
600 (W)
×
1,700 (D)
×
1,780 (H) mm
(excluding the status indicator (345 mm) and other protrusions)
Machine dry
mass
Main body
Approx. 1,300 kg
Paint color
Munsell No. 2.5 GY 8.0/0.5 and N2.4
Summary of Contents for DAG810