B-29
1-6-2. Connection of Power Cable of Vacuum Unit
[Optional Accessory]
Equipment you must have ready
Phillips screwdriver
Slotted screwdriver
Procedures to connect the power cable of the vacuum unit to the machine
Step No.
Procedure
(Continued from the previous section)
1
Connect the PE line of the vacuum unit power cable to the earth bar located at the bottom
part of the control box.
Earth bar
(Terminal for connection)
E: No. 50
2
Connect each power line of the vacuum unit power cable to the corresponding terminals
on the terminal block (TB2).
・
Make sure to connect each line to its terminal correctly referring to the following figure.
Terminal block (TB2)
(Terminals for connection)
L1: No. 3
L2: No. 6
L3: No. 9
3
Connect the signal line of the vacuum unit to the connector (J108) on the panel located at
the bottom part of the control box.
Connector panel
[Bottom part as viewed from below]
Continued in the next section.
Summary of Contents for DAG810
Page 85: ......