CALIBRATION PROCEDURE
The system must be calibrated to obtain the right dosage of liquid in the crop.
1.
Fill the reservoir with water, 10-15l (3-4gal.) are sufficient.
2.
Adjust the pressure to the pressure corresponding to the desired flow (Figure 71).
3.
Put an empty bucket (item 1) under the nozzle (item 2) to collect the liquid (inside the accelerator
chamber if standard nozzle location is used).
4.
Run the system for one minute to collect all the water.
5.
Measure the volume collected.
6.
Modify the pressure of the system until the desired flow is obtained.
Figure 72 Flow calibration