SETUP
56
CONTROLLER - FIGURE 69
The metal detector is managed by the electronic controller located on the harvester above the hydraulic
manifold. It controls the transmission F-N-R and the emergency stop system. An indicator light on the
controller shows the state of the system.
Green – Active
Orange – Feedroll stop pawl locked or feedroll speed reading error.
Red – Metal detected
The metal detector can be set to three different sensitivity levels for best performance according to specific
conditions. It uses a variable threshold that adjusts itself to the harvest conditions (length of cut, vibrations,
impacts, etc.) to maximise the detection power. The sensitivity can however be reduced to minimise the risks
of false detections and useless stops in specific difficult conditions (Heavy wear of the feedolls for example).
The variable threshold system is based on the rotation of the feedrolls and thus requires the feedroll speed
sensor to work. In case of a faulty speed sensor, the system remains functional but at a lower sensitivity and
reliability fixed threshold.
Manual
N
o. F6918E003E v1.2
Summary of Contents for Scorpion 300
Page 1: ...Operator s Manual FORAGE HARVESTER Manual No F6918E003E v1 2...
Page 2: ...Manual No F6918E003E v1 2 2...
Page 5: ...Manual No F6918E003E v1 2 5...
Page 11: ...Manual No F6918E003E v1 2 11...
Page 18: ...SAFETY RULES 18 Figure 5 Safety Decals Figure 6 Safety Decals Manual No F6918E003E v1 2...
Page 19: ...SAFETY RULES 19 Figure 7 Safety Decals Figure 8 Safety Decals Manual No F6918E003E v1 2...
Page 20: ...SAFETY RULES 20 Figure 9 Safety Decals Manual No F6918E003E v1 2...
Page 21: ...SAFETY RULES 21 Figure 10 Safety Decals Manual No F6918E003E v1 2...
Page 109: ...Manual No F6918E003E v1 2 109...