DINO 105T
17
MEASURES TO BE TAKEN IF THE LIFT IS AT RISK OF LOSING ITS
STABILITY
The reason for the reduced stability can be a fault in the lift, the wind or other lateral force, collapse of
the standing base or negligence in providing sufficient support. In most cases a sign of the reduced
stability is the inclination of the lift.
1.
If there is time, try to find out the reason for the reduced stability and the direction of its effect.
Warn other people on the work site using the alarm signal.
2.
Reduce the outreach to the side by retracting the telescope. Avoid abrupt movements.
3.
Turn the boom away from the danger zone, i.e. to a position where the stability of the lift is
normal.
4.
Lower the boom.
If the stability has been lost as a result of a fault in the lift, repair such a fault immediately.
Do not use the lift until the fault has been repaired and the condition of the lift has been verified.