6. Trial run
The test run function is used to verify the performance of the drive. Turn OFF the 8th gear
switch in the power-off state. Then when the power is turned on without pulse input, turn the
SW8 gear dial switch from ON to OFF, and then set OFF to ON from 1 second, then start the
trial operation function (the motor rotates at 1 revolution / second Speed cycle forward and
backward).
7. Idle current
The driver will automatically enter idle current after 500 milliseconds without pulse input to
reduce motor heating. The current is restored to the set value during pulse input.
8. Indicator function
This product has 2 red and green LEDs to indicate the light display status:
Status indication:
Method: Complete the corresponding number of flashes (0.5 second low level, 0.5 second
high level) in different states, complete 2 seconds high level, and then recycle.
Status function
Green light
Communication code
Description
Stopping
flicker
2
On, the motor is phase locked but the
motor is not running
In operation
Chang Liang
3
Drive is running
Enable disconnect
flicker
1
Enable disconnect, motor can be free
error indication
:
Method: Complete the corresponding number of flashes (0.5 second low level, 0.5 second
high level) in different states, complete 2 seconds high level, and then recycle.
Alarm function
Red light
Communication code
Description
Motor overcurrent
1 green +1 red
10
Motor phase current overcurrent or drive
failure
Motor phase loss
1 green +2 red
11
Motor is not connected
Over pressure
1 green +3 red
14
Power input is greater than 90V
Undervoltage
1 green +4 red
13
Power input is less than 18V
Other alarms
1 green +5 red
other