Standard product:
RJ45 type × 2 Pin position from the insertion angle
Setting switch
4. mailing address
Users can control up to 30 HSD286pro drives at the same time using RS-485 bus. The drivers
communication address is set by a 5-digit DIP switch.
The address setting range is 1-32, where address 32 is reserved for the system. When the
drive address setting is greater than 31, it needs to be set and saved using the upper-level
debugging software.
And the switch should be all set to OFF (default is 1).
Notes
1) One controller can control up to 30 HSD286pro drives at the same time through
the RS-485 bus.
2) The communication address setting of each driver must be unique, otherwise it
will cause communication error.
DIP switch
address
SW1
SW2
SW3
SW4
SW5
ON
ON
ON
ON
ON
1
ON
ON
ON
ON
OFF
2
ON
ON
ON
OFF
ON
3
ON
ON
ON
OFF
OFF
4
ON
ON
OFF
ON
ON
5
ON
ON
OFF
ON
OFF
6
Notes
When multiple units are connected in series,
when pins 3 and 8 of the last OUT port are
short-circuited, and pins 6 and 7 are short-
circuited, it is the access terminal resistance.
The IN port does not include a terminating
resistor.
Schematic and Interface Definition