Standstill and speed monitoring
Original instruction manual
Date: 2017.08.28
Page 12 of 28
7
Standstill and speed monitoring
DNSL-
ID-No.:
Terminals/ connectors
Description
all
B11-B18
Safe digital inputs for safety functions
all
P1, P2
Terminal for 24V DC to supply the outputs
DS
24DS07
2 safe monitoring for standstill, speed, position, direction and
brake in different function modes
Sin/cos or TTL measuring systems, HTL signals via HTL cable
adapter
DR
24DR01
2 safe monitoring for standstill, speed, position, direction and
brake in different function modes
Resolver Measuring system
SI
24SI02
2 safe monitoring for standstill, speed, position, direction and
brake in different function modes
SSI interface Measuring system
DS/ SI
O1-O4
Semi-conductor outputs configurable as safe or clock outputs
DR
O1-O2
Semi-conductor outputs configurable as safe or clock outputs
7.1
Schematic, display and front view
Display
DNSL-DS
DNSL-DR
DNSL-SI
B11-14
Signal=0V
Signal=24V
DNSL-DS
ON
P1 24VDC
P2 24VDC
O1
O2
O3
O4
B11
B12
B13
B14
B21
B22
B23
B24
1
2
oder/or
E
in
g
ä
n
g
e
/
In
p
u
ts
1
2
DNSL-DR
ON
P1 24VDC
P2
O1
O1
O2
O2
B11
B12
B13
B14
B21
B22
B23
B24
1
2
E
in
g
ä
n
g
e
/
In
p
u
ts
1
2
DNSL-SI
ON
P1 24VDC
P2 24VDC
O1
O2
O3
O4
B11
B12
B13
B14
B21
B22
B23
B24
1
2
E
in
g
ä
n
g
e
/
In
p
u
ts
1
2
SSI 1
SSI 2
B21-24
Signal=0V
Signal=24V
O1-4
I=0
I>0 ≤ max.
P1/P2
O-Pwr = 0V
Pwr = 24V
1 Pwr: 0V*
1
Pwr: 24V*
2
n>0
2
n=0
3
n>max.
3
n<max.
2
3
Measuring system
OK
2 3
No
measuring system
See also Designer instruction manual.