Cable adapter
Original instruction manual
Date: 2017.08.28
Page 21 of 28
12.11
DNCO Function to monitor the Peripheral speed
Modules
8 Speed
16 Speed
48 Speed
DNSL-ZMx
I1
I2
I3
I1
I2
I3
I4
I1
I2
I3
I4
I5
DNSL-DS/ DR
B11
B12
B13
B11
B12
B13
B14
B11
B12
B13
B14
B21
DNSL-IN
I11
I12
I13
I11
I12
I13
I14
I11
I12
I13
I14
I15
DNSL-IO/ IO2
I21
I22
I23
I21
I22
I23
I24
I21
I22
I23
I24
I25
•
The DNCO function enables the monitoring up to 2 x 48 different speeds.
•
2 drives can be monitored.
•
Setting of 8, 16 or 48 speeds is available.
•
Up listed inputs are to set the speeds.
•
DNCO1 unit can be used to set the inputs.
•
The configuration happens at the Designer.
DNCO1
Input at the speed monitoring
Input at the central modules
D1
B11
D2
D3
D4
D5
D6
B12
B13
B14
B21
B22
DNSL-DS
DNCO1
SH-K
Steuer-
elektronik
Control
device
DNSL-DR
DNSL-SI
D1
I1
D2
D3
D4
D5
D6
I2
I3
I4
I5
I6
DNSL-ZM
ZMB
ZMT
ZMA
ZMK
ZMR
DNCO1
SH-K
TK
Steuergerät
Control
device
12.12
Analogue inputs for DNCO-function at DNSL-ZMA
•
The voltage analogue input UA enables the selection of up to 8 different speeds.
•
The value of these motions can be entered in the table DNCO1 at the Designer via the teach function
automatically.
•
The monitoring happens at DNSL-DS or DR.
•
For detail about speed monitoring see
www.dina.de/
download
13
Cable adapter
The DNDA is used as an interconnection between the drive measuring system and the speed monitoring system.
There are different versions of cable adapter available. See cable adapter instruction manual.
DNDA 9/8
DNDA 15/8
DNDA 25/8
DNRJ45-HTL-SL is to use with HTL incremental Measuring systems
DNRJ45 HTL-SL
Kabelfarben
ID-No.:
95RJ20
ws/or
: 0V
ws/gn
: A
gn
: A
ws/bn
: B
bn
: B