Outputs at SAFELINE
Original instruction manual
Date: 2017.08.28
Page 23 of 28
15
Outputs at SAFELINE
DNSL-
I: A
Performance Level
Beschreibung
ZM/ ZMA/ ZMK
ZMB/ ZMR /ZMT
O1
0.1A
PLc
1 output, System OK
ZM
O2-O5
1A /∑2A
PLe
4 safe outputs,
ZM/ ZMR
O6/ O7
0.25A
PLc / PLe
(2)
2 outputs, 2 clock or
1 safe output
ZMA/ ZMK
O2/ O3
1A /∑1A
PLe
2 safe outputs
ZMB
O2/ O3
1A /∑1A
PLe
2 safe outputs
ZMB/ ZMK/ ZMT
13
14
23
24
≥10mA≤6A
DC13: 24V/5A
PLe
2 output with 2 safe contacts
ZMR
O2-O5
1A /∑2A
PLe
4 safe outputs
KM
13/ 23
14/ 24
33/ 43
34/ 44
53/ 63
54/ 64
73/ 83
74/ 84
O1-O4
≥10mA≤6A
13 – 44: ∑6A
53 - 84: ∑6A
DC13: 24V/ 5A
0.1A
PLe
PLc
4 outputs every with
2 safe contact
4 diagnostics contact outputs
DS / SI
O1-O4
1A, ∑2A
PLc / PLe
4 outputs, 4 clock or
2 safe outputs
DR
O1/O2
1A, ∑1A
PLc / PLe
2 outputs, 2 clock or
1 safe outputs
IN
O11/ 12/ 21/ 22
0.25A
PLc / PLe
4 outputs, 4 clock or
2 safe outputs
IO
O11/ 13/ 15/ 17
O12/ 14/ 16/ 18
1A, ∑4A
PLc / PLe
8 outputs or 4 safe outputs
IO/ IO2
O21/22
0.25A
PLc / PLe
2 outputs, 2 clock or
1 safe output
IO2
O11-O14
2A /∑4A
PLe
4 safe outputs
RM230
13
14/ 23
24
33
34/ 43
44
53
54/ 63
64
73
74/ 83
84
13
14/ 33
34
23
24/ 43
44
53
54/ 73
74
63
64/ 83
84
≥10mA≤6A
DC13: 24V/5A
AC15: 230V/3A
∑ 6A
PLc
PLe
4 Ausgänge je 2 NO Kontakte
Konfiguration als
2 Ausgänge je 2 sichere
NO Kontakten
•
The outputs can be used for safety relevant control functions as emergency stop, protection cover,
permission, drives authorization, net authorization, to unlock of protection cover and other safety functions.
•
All semi-conductor outputs are positive switching.
Designer Symbol
Sicherer Ausgang
Taktausgang
Sicherer Kontakt
Sichere Kontakte
Sichere Kontakte RM
Safe output
Clock output
Safe contact
Safe contact
Safe contact RM