Useful tip: to ensure long-term operation of the generator 

engine, it is important to observe the following tips:

- Before connecting the load, allow the engine to run for 1-2 minutes to warm it up.
-  When disconnecting the load after lengthy operation, do not turn off the generator. Allow 

the generator to run idle for 1-2 minutes so that it cools down.

IMPORTANT!

5. Pull the manual starter until a slight resistance is felt, then pull 

it toward you relatively sharply. Slowly turn the manual starter by 

hand, do not release it abruptly.
6. Turn the air choke control knob to the “RUN” position.

Fig.  3

Do not connect two or more devices at a time. The start-

up of many devices requires high power. Devices should be 

connected one at a time according to their power rating. 

Do not connect any power consumers within the first 

2 minutes after the generator has been started.

ATTENTION – DANGER!

“ON” MODE
When the ECON switch is in the “ON” position, the control unit monitors the engine speed, reducing it 

commensurate with the connected load. If the engine speed is not enough to generate electricity to provide 

the load, the control unit will automatically increase the engine speed. 
As a result, fuel consumption is optimized and noise levels are reduced.

The ECON switch must be set to “OFF” to increase 

engine speed to nominal. When connecting multiple 

power consumers to the generator, be sure to first 

connect the one with the highest starting current, and 

the device with the lowest starting current should be 

connected last.

IMPORTANT!

ECON FUNCTION

1. Start the engine.

2. Set the ECON switch to “ON”.

3. Plug the device into an AC outlet.

4. Make sure the AC indicator light is on.

5. Turn on the electrical device.

FUNCTIONAL DESCRIPTION 

OF INVERTER GENERATORS

8

“OFF” MODE
The ECON switch must be set back to “OFF” when using electrical devices requiring a high starting current, 

such as a compressor or submersible pump.

The ECON switch must be set back to “OFF” when using 

electrical devices requiring a high starting current, such 

as a compressor or submersible pump.

IMPORTANT!

www.ks-power.de/en

   

|

    24

Summary of Contents for Konner & Sohnen 4260405363322

Page 1: ...KS 4100iE KS 8100iE Inverter Generator Inverter Generator in Soundproof Housing EN Please read this manual carefully before use Owner s Manual KS 2000i S KS 4000iE S...

Page 2: ...the generator on a flat hard surface away from flammable liquids gases at a minimum distance of 1 m Keep unauthorized persons children and animals away from work area Wear safety shoes and gloves We...

Page 3: ...s and or improvements in design components set and technical attributes without notice and without incurring obligation The pictures in this manual are schematical and may not match the parameters of...

Page 4: ...ts 6 Ground terminal 7 Generator parallel socket 8 Reset button 9 12V 8A DC outlet MODEL KS 4000iE S MODEL KS 2000i S 1 Fuel tank cap air vent 2 Carrying handles 3 Control panel 4 Manual starter 5 Air...

Page 5: ...1 0 4 0 6 Power factor cos 1 1 1 1 Dimensions L W H mm 600 420 425 685 500 553 510 310 525 630 475 570 Lithium battery Ah 1 6 1 6 1 6 Net weight kg 38 68 18 40 Protection class IP23M Nominal voltage...

Page 6: ...ghts up and then the engine stops automatically The engine will not start until oil is added AC INDICATOR When the generator is running and producing electricity the AC indicator light is on If the DC...

Page 7: ...parts IMPORTANT CHECKING THE OIL LEVEL The generator is transported free of motor oil Do not start the engine until it is filled with sufficient amount of motor oil 1 Unscrew the oil dipstick and wip...

Page 8: ...alls or does not start turn the engine switch to the ON position and then pull the manual starter If the oil level indicator flickers for several seconds add oil and restart the engine IMPORTANT FOR M...

Page 9: ...ntrol unit monitors the engine speed reducing it commensurate with the connected load If the engine speed is not enough to generate electricity to provide the load the control unit will automatically...

Page 10: ...inal output power of these models When connecting generators of different capacities using the Parallel function the output power is two times the nominal power of the generator with lesser capacity W...

Page 11: ...the battery terminals securely so that they are not disconnected due to motor vibrations or other actions To charge the battery properly follow the instructions in the battery manual The DC protector...

Page 12: ...y in order to provide the correct generator operation It is necessary to check the oil levels according to technical maintanance schedule The detailed description of oil filling and draining can be fo...

Page 13: ...er of the damper Descale the screen and flame arrester of the damper with a wire brush Inspect the screen and flame arrester of the damper Replace them if they are damaged Replace the flame arrester R...

Page 14: ...l or illegible inscriptions in the warranty card or tear off coupon no warranty repair is carried out no objections to quality are accepted and the warranty card is withdrawn by the service center as...

Page 15: ...sters To quick wear parts and components spark plugs nozzles pulleys filter and safety elements batteries removable devices belts rubber seals clutch springs axles manual starters oils gear To prevent...

Page 16: ......

Page 17: ...Stare Babice www ks power pl info pl dimaxgroup de 47 02222 www ks power com ua sales ks power com ua 129090 19 1 1 1 6 99 www ks power ru info ks power ru CONTACTS Deutschland DIMAX International Gmb...

Reviews: