It is recommended to ground the generator before operating it for the first time. Before starting the device, 

remember that the total power of the connected power consumers should not exceed the nominal power 

of the generator.

TERMS OF USE 

OF INVERTER GENERATOR

4

GENERATOR OPERATION

5

To avoid electric shock due to poor-quality electrical 

appliances or improper use of electricity, the generator 

must be earthed using a high-quality insulated conductor.

IMPORTANT!

Make sure that the control panel, the blinds and the 

underside of the inverter are well cooled and protected 

against the ingress of small solids, dirt, and water. 

Improper operation of the cooler can cause damage to 

the motor, inverter or alternator.

IMPORTANT!

DC FUSE
The DC protector automatically switches to “OFF” when the current of the operating electrical device is 

higher than the rated current. To use this equipment again, turn on the DC fuse again by pressing the “ON” 

button.

OIL LEVEL INDICATOR
When the oil level falls below the level required for operation, the oil level indicator lights up, and then the 

engine stops automatically. The engine will not start until oil is added.
AC INDICATOR
When the generator is running and producing electricity, the AC indicator light is on.

If the DC fuse turns off, reduce the load of the connected 

electrical device. If the DC protector turns off again, stop 

operation and contact your nearest Könner & Söhnen 

service center.

IMPORTANT!

OVERLOAD INDICATOR
The overload indicator lights up when the connected generator is overloaded, the inverter control unit 

overheats or the AC output voltage rises.
If the overload indicator goes on, the engine will continue to operate, but the generator will no longer 

produce electricity. In this case, you must perform the following steps:
1. Turn off all connected electrical appliances and stop the engine.

2. Reduce the total power of the connected devices until the nominal power of the generator is reached.

3. Check if the vent grid is clogged. Remove excess dirt or debris, if any.

4. After checking, start the engine.

The overload indicator may light up within several 

seconds after start-up or when connecting electrical 

devices requiring a high starting current, such as a 

compressor or voltage indicator. However, this is not a 

malfunction.

IMPORTANT!

www.ks-power.de/en

   

|

    21

Summary of Contents for Konner & Sohnen 4260405363322

Page 1: ...KS 4100iE KS 8100iE Inverter Generator Inverter Generator in Soundproof Housing EN Please read this manual carefully before use Owner s Manual KS 2000i S KS 4000iE S...

Page 2: ...the generator on a flat hard surface away from flammable liquids gases at a minimum distance of 1 m Keep unauthorized persons children and animals away from work area Wear safety shoes and gloves We...

Page 3: ...s and or improvements in design components set and technical attributes without notice and without incurring obligation The pictures in this manual are schematical and may not match the parameters of...

Page 4: ...ts 6 Ground terminal 7 Generator parallel socket 8 Reset button 9 12V 8A DC outlet MODEL KS 4000iE S MODEL KS 2000i S 1 Fuel tank cap air vent 2 Carrying handles 3 Control panel 4 Manual starter 5 Air...

Page 5: ...1 0 4 0 6 Power factor cos 1 1 1 1 Dimensions L W H mm 600 420 425 685 500 553 510 310 525 630 475 570 Lithium battery Ah 1 6 1 6 1 6 Net weight kg 38 68 18 40 Protection class IP23M Nominal voltage...

Page 6: ...ghts up and then the engine stops automatically The engine will not start until oil is added AC INDICATOR When the generator is running and producing electricity the AC indicator light is on If the DC...

Page 7: ...parts IMPORTANT CHECKING THE OIL LEVEL The generator is transported free of motor oil Do not start the engine until it is filled with sufficient amount of motor oil 1 Unscrew the oil dipstick and wip...

Page 8: ...alls or does not start turn the engine switch to the ON position and then pull the manual starter If the oil level indicator flickers for several seconds add oil and restart the engine IMPORTANT FOR M...

Page 9: ...ntrol unit monitors the engine speed reducing it commensurate with the connected load If the engine speed is not enough to generate electricity to provide the load the control unit will automatically...

Page 10: ...inal output power of these models When connecting generators of different capacities using the Parallel function the output power is two times the nominal power of the generator with lesser capacity W...

Page 11: ...the battery terminals securely so that they are not disconnected due to motor vibrations or other actions To charge the battery properly follow the instructions in the battery manual The DC protector...

Page 12: ...y in order to provide the correct generator operation It is necessary to check the oil levels according to technical maintanance schedule The detailed description of oil filling and draining can be fo...

Page 13: ...er of the damper Descale the screen and flame arrester of the damper with a wire brush Inspect the screen and flame arrester of the damper Replace them if they are damaged Replace the flame arrester R...

Page 14: ...l or illegible inscriptions in the warranty card or tear off coupon no warranty repair is carried out no objections to quality are accepted and the warranty card is withdrawn by the service center as...

Page 15: ...sters To quick wear parts and components spark plugs nozzles pulleys filter and safety elements batteries removable devices belts rubber seals clutch springs axles manual starters oils gear To prevent...

Page 16: ......

Page 17: ...Stare Babice www ks power pl info pl dimaxgroup de 47 02222 www ks power com ua sales ks power com ua 129090 19 1 1 1 6 99 www ks power ru info ks power ru CONTACTS Deutschland DIMAX International Gmb...

Reviews: