Thank you for your purchase of 

Könner & Söhnen

 products. This manual contains a brief description of 

safety, use and debugging. More information can be found on the official manufacturer’s website in the 

support section: 

ks-power.de/betriebsanleitungen

.

You can also go to the support section and download the full version of the manual by scanning the QR 

code, or on the website of the official importer of Könner & Söhnen products:

 www.ks-power.de/en

.

Manufacturer reserves the right to make alterations into the generators, which may not be reflected in this 

manual. Pictures and photos of the product may vary from its actual appearance. At the end of this manual, 

You may find contact information which you are free to use in case of any issues occurrence. 
All data, specified in this operation manual is the most up to date for the moment of its publishing. The 

current list of service centers you can find at the website of official importer: 

www.ks-power.de/en

.

Do not use the generator in rooms with poor ventilation or in conditions of excessive humidity. Do not 

place the generator in water or on moist soil. Do not expose the generator to rain, snow, as well as to direct 

sunlight for a long time. Place the generator on a flat, hard surface, away from flammable liquids/gases 

(at a minimum distance of 1 m). Keep unauthorized persons, children, and animals away from work area. 

Wear safety shoes and gloves.

We care about the environment, therefore, we consider it expedient to save

paper and leave in print a short description of the most important sections.

Be sure to read the full version of the manual before

getting started!

Failure to follow the recommendations marked with this

sign may lead to serious injury or death of the operator

or third parties.

Useful information while operating the machine.

ATTENTION – DANGER!

IMPORTANT!

ELECTRICAL SAFETY

1.1

The generator produces electricity that may lead to an electric shock while neglecting compliance regulations. 

All connecting the generator to the network must be made by certified electrician in accordance with all elec

-

trical rules and regulations. Connect the generator to the protective ground before operation. Wires with 

damaged or spoiled insulation should be replaced. You should also replace worn, damaged or rusty contacts.

The device generates electricity. Follow safety precautions 

to avoid electric shock.

Using device for other purposes deprives the right for

free warranty.

ATTENTION – DANGER!

IMPORTANT!

Be careful. Do not operate the generator, if you are tired,

under the influence of drugs or alcohol. Inattention may

cause a serious injury.

ATTENTION – DANGER!

www.ks-power.de/en

   

|

    17

Summary of Contents for Konner & Sohnen 4260405363322

Page 1: ...KS 4100iE KS 8100iE Inverter Generator Inverter Generator in Soundproof Housing EN Please read this manual carefully before use Owner s Manual KS 2000i S KS 4000iE S...

Page 2: ...the generator on a flat hard surface away from flammable liquids gases at a minimum distance of 1 m Keep unauthorized persons children and animals away from work area Wear safety shoes and gloves We...

Page 3: ...s and or improvements in design components set and technical attributes without notice and without incurring obligation The pictures in this manual are schematical and may not match the parameters of...

Page 4: ...ts 6 Ground terminal 7 Generator parallel socket 8 Reset button 9 12V 8A DC outlet MODEL KS 4000iE S MODEL KS 2000i S 1 Fuel tank cap air vent 2 Carrying handles 3 Control panel 4 Manual starter 5 Air...

Page 5: ...1 0 4 0 6 Power factor cos 1 1 1 1 Dimensions L W H mm 600 420 425 685 500 553 510 310 525 630 475 570 Lithium battery Ah 1 6 1 6 1 6 Net weight kg 38 68 18 40 Protection class IP23M Nominal voltage...

Page 6: ...ghts up and then the engine stops automatically The engine will not start until oil is added AC INDICATOR When the generator is running and producing electricity the AC indicator light is on If the DC...

Page 7: ...parts IMPORTANT CHECKING THE OIL LEVEL The generator is transported free of motor oil Do not start the engine until it is filled with sufficient amount of motor oil 1 Unscrew the oil dipstick and wip...

Page 8: ...alls or does not start turn the engine switch to the ON position and then pull the manual starter If the oil level indicator flickers for several seconds add oil and restart the engine IMPORTANT FOR M...

Page 9: ...ntrol unit monitors the engine speed reducing it commensurate with the connected load If the engine speed is not enough to generate electricity to provide the load the control unit will automatically...

Page 10: ...inal output power of these models When connecting generators of different capacities using the Parallel function the output power is two times the nominal power of the generator with lesser capacity W...

Page 11: ...the battery terminals securely so that they are not disconnected due to motor vibrations or other actions To charge the battery properly follow the instructions in the battery manual The DC protector...

Page 12: ...y in order to provide the correct generator operation It is necessary to check the oil levels according to technical maintanance schedule The detailed description of oil filling and draining can be fo...

Page 13: ...er of the damper Descale the screen and flame arrester of the damper with a wire brush Inspect the screen and flame arrester of the damper Replace them if they are damaged Replace the flame arrester R...

Page 14: ...l or illegible inscriptions in the warranty card or tear off coupon no warranty repair is carried out no objections to quality are accepted and the warranty card is withdrawn by the service center as...

Page 15: ...sters To quick wear parts and components spark plugs nozzles pulleys filter and safety elements batteries removable devices belts rubber seals clutch springs axles manual starters oils gear To prevent...

Page 16: ......

Page 17: ...Stare Babice www ks power pl info pl dimaxgroup de 47 02222 www ks power com ua sales ks power com ua 129090 19 1 1 1 6 99 www ks power ru info ks power ru CONTACTS Deutschland DIMAX International Gmb...

Reviews: