Operating Instructions
30
DigiTrak
®
F5
®
SST
®
Operator’s Manual
Using the pull-down menu under Serial Port Connection, select Communications Port (COM1), and then
click on the connect button below to connect to the cable box. Verify that you see live data, as shown in
the dialog box below. If you do not, then verify the setup and port selection and try again.
Steering Tool Data Upload Control Dialog Box (connected)
See the
Inputting and Editing Drill Data
section later in this manual for complete information on using the
job information and data upload control dialog boxes.
Select to input and
record a different
heading value than
displayed here
Rod length to be
recorded at next
logged point
Log button
– select to log
a data point with the data
shown on this screen
Pull Back button
– select
to remove the last logged
data point (pulled back
rods may be restored
until a new data point
is logged)