DGM INSTALLATION AND MAINTENANCE MANUAL
700135-0000 Rev. O
31
To view or change Function 16, press
“16”, then FUNC or, if you are viewing the
previous function, just press FUNC. The second line of the
display will read “16 -
Burg Panel.” A message will scroll on the first line:
The Burg/Panel option is Disabled. Press the TGGL button to
change. Press CLR/ SIL to clear display or FUNC to view next
Function.
Press TGGL to select/deselect the Burglary Panel Option. Press CLR/SIL to clear
the display. Press FUNC to advance to the next function.
4.3.18 FUNCTION 17 (SETTING OPEN / CLOSED TELEGRAPH INDEX)
When Relay 0 (K1) is set for telegraph output, Function 17 determines whether the
relay will transmit in Open or Closed Index.
To view or change Function 17, press “17”", FUNC or, if you are viewing the
previous function, just press FUNC. The second line of the display
will read “17 - Set
Tel
Index.” A message will scroll on the first line:
Telegraph index is closed. Press the TGGL button to change. Press
CLR/SIL to clear display or FUNC to view next Function.
Press TGGL to alternately select Open or Closed Index. Press CLR/SIL to clear the
display. Press FUNC to advance to the next function.
4.3.19 FUNCTION 18 (RESETTING PANEL TO FACTORY DEFAULTS)
Selecting Function 18 will return the DGM panel settings to the default factory
settings. The default factory settings are as follows:
Function 0 (DGM Number)
8191
Function 1 (1st Zone Number)
0001
Function 2 (Time)
Not Used
Function 3 (Passnumber)
123456
Function 4 (Beep or No Beep)
Disabled
Function 5 (Data Synchronization Bit) Bit Enabled
Function 6 (Tamper Sensitivity)
65
Function 7 (Clock Status)
Active
Function 8 (Telegraph Speed)
6 (7/8 second)
Function 9 (On / Off Ratio)
5 (50%)
Function10 (Baud Rate)
03 (1200 baud)
Function 11 (Request To Send)
40 milliseconds
Function 12 (Zone Delays)
All zones 0 seconds delay
Function 13 (Zones To Bypass)
Not Used
Function 14 (Communication Format)
Multiplex Enabled
Function 15 (Global Commands)
Enabled
Function 16 (Burg Panel)
Disabled
Function 17 (Open or Closed Index)
Closed
Function 18 (Reset to Defaults)
Used to Reset All Functions
Function 19 (Relay on Zone Trouble)
Disabled
Function 20 (Relay on Zone Alarm)
Disabled
Function 21 (Call Out Option)
Enabled
Function 22 (Open or Closed Zone)