Communication Protocol Setup
1
2
3
4
5
6
ON
ON
7
8
Communication Baud rate Setup
1
2
3
4
5
6
ON
ON
7
8
RS-485 Termination Resistor
1
2
3
4
5
6
ON
ON
7
8
RS-485 Termination Resistor (On/Off)
Select the appropriate Protocol with DIP switch combination.
Switch State
Protocol
SW-1
SW-2
SW-3
Sw-4
OFF OFF OFF OFF Auto
Protocol
ON OFF OFF OFF
PELCO-D
OFF ON OFF OFF
PELCO-P
ON ON OFF OFF
SAMSUNG
If you set the protocol as Auto Protocol, camera will
automatically recognize the type of Protocol.
Auto Protocol supports Pelco-D and Samsung Protocol.
If you want to control using DVR or system keyboard, their
protocol must be identical to camera. Otherwise, you cannot
control the camera.
If you changed camera protocol by changing DIP S/W, the
change will be effective after you reboot the camera.
Factory default of protocol is “Auto Protocol”
INSTALLATION
2
Pin 8 is used for ON/OFF of RS-485 Termination. Normally, it
must be OFF state. Especially when you have trouble with long
Daisy chain style connection, turn ON this termination switch of
last camera.
Pin 8
Select the appropriate Baud rate with DIP switch combination.
Switch State
Protocol
SW-5
SW-6
SW-7
OFF OFF OFF
2400
BPS
ON OFF OFF
4800
BPS
OFF ON OFF
9600
BPS
ON ON OFF 19200
BPS
OFF OFF ON
38400
BPS
Factory default of Baud rate is “9600 BPS”