DWC-PTZ10x [Mini SPEED DOME CAMERA]
www.Digital-Watchdog.com
11/49
DIP Switch Setup
Before you install the camera, you should set the DIP switches to configure the camera ID, Baud rate,
and communication protocol.
ID Setting (1~255)
Protocol
Buad Rate
RS-485
Terminate
0x00 : 2400
0x01 : 4800
0x02 : 9600
0x03 : 19200
0x04 : 38400
0x00 : Auto Select
0x01 : Pelco-D
0x02 : Pelco-P
0x03 : SAMSUNG
0x04 : VCLTP
0x05 : KD6
Camera ID Setup
1
2
3
4
5
6
ON
ON
7
8
ID number of camera is set using binary number. The example
is shown below.
SW
1
2
3
4
5
6
7
8
ID
Value 1 2 4 8 16
32
64
128
ex)
ID=5 on off on off off off off off
ex)
ID=10 off on off on off off off off
The range of ID is 0~255. Factory default of Camera ID is 1.
If you want to control a certain camera, you must match the
camera ID with Cam ID setting of DVR or Controller.
INSTALLATION