GP-377 Series Users Manual
5-20
Chapter 5 - Installation and Wiring
GP TOUCH MONOPOLIZE
The monopolizing of touch panel use can be set ON or OFF. When you want to
use the PLC exclusively with a Momentary operation setup on the touch panel,
turn GP TOUCH MONOPOLIZE ON.
When this setup is ON, the touch panel uses the PLC exclusively whenever the
momentary operation setup on the panel is pressed. In this way, you can use the
inching operation with a momentary switch. When you stop pressing the panel,
exclusive use ends.
GP-PRO/PBIII for Windows PLC Connection Manual (included
with screen creation software)
MONOPOLIZE TIME (0-2550S)
This field controls the length of time for the monopolize process when no other
touch panel operations are performed. The Monopolize process begins when the
System Data Area's 7th bit of word address LS14 turns ON, and ends either when
the bit turns OFF, or when the time set here elapses.
• Pressing the touch panel in the middle of the monopolize process interrupts the
MONOPOLIZE TIME function, and ends exclusive use.
• When MONOPOLIZE TIME is set to 0, the monopolize function does not end
automatically.
For further imformation about the contents of System Data Area LS6 (status) and
LS14 (control)
GP-PRO/PBIII for Windows PLC Connection
Manual
(included with screen creation software)
Speed Difference between Display Priority and Operation Priority
When using the Mitsubishi Electric Corp. A3A PLC, with consecutive addresses
(80 words not included in the System Area), the difference in reading speed is as
shown in the following graphs.