6.2 Configuring PCAP II for Different Baud Rates
This section is intended for advanced users, only.
The PCAP II system is capable of operating at RS232 symbol rates of
9600, 14400, 19200, and 38400 baud. Each PCAP II is factory-
configured to operate at 38400 baud, which works well for most PCs.
However, some applications (such as modem or network links) may
require the use of a different baud rate.
Change the PCAP II baud rate as follows:
1. First, reset the internal DIP switches of the external
processor for the new baud rate as follows:
a. Power off the PCAP II external processor and disconnect
all cables, especially the EXTERNAL POWER and
RS232 cables.
b. Carefully remove the external processor top cover.
c. Locate the 5-position DIP switch at the front of the
internal printed-circuit board. Set DIP switch positions 1-
3 to desired baud rate as follows:
d. Replace top cover and reconnect all cables.
2. Next, configure the PCAP II Master Control program for the
new baud rate as follows:
a. Make sure that the PCAP II external processor is
powered OFF.
Baud Rate
DIP1
DIP2
DIP3
9600
OFF
OFF
ON
14400
ON
ON
OFF
19200
OFF
ON
OFF
38400
ON
OFF
OFF
38400 (default)
OFF
OFF
OFF
Table 6.1 Baud Rate DIP Switch Settings
Summary of Contents for PCAP II
Page 2: ......
Page 4: ......
Page 14: ...2 ...
Page 68: ...56 Figure 4 14 Lowpass Filter Graphical Description ...
Page 71: ...59 Figure 4 16 Highpass Filter Graphical Description ...
Page 75: ...63 Figure 4 18 Bandpass Filter Graphical Description ...
Page 90: ...78 Figure 4 28 Slot Filter Graphical Description ...
Page 104: ...92 ...
Page 110: ...98 ...
Page 128: ...116 ...
Page 154: ...142 ...