This function enables the user to test the integrity of a string of DigiShot
®
Plus detonators that have been
tagged. The Tagger will test DigiShot
®
Plus detonators connected on the Harness wire that correspond with
tagged detonators in the Detonator list.
DigiShot
®
Plus detonators connected to the Harness Wire, which are not in the
detonator list, will be ignored. Use Autosearch or Check Pattern to locate newly
connected detonators.
The user can select the channel to test in the test all / row menu only if multiple
channels are used.
An option to halt on errors while testing is available and may be configured as “Halt
on test” under the DigiShot Setup menu.
During tagging, at the end of Test All / Row, Autosearch and Check Pattern, a
duplicate check is performed and the software will check the entire list across all
channels for ‘location exists’ errors, to avoid duplicate detonators.
1. Main Menu
Press
to select
Test Menu
.
2. Test Menu
Connect all detonators to be tested to the harness wire.
Press
to select Test All in List.
3. Test All
Use numerical keys to enter Channel number.
Press
to continue.
Channel number will only be requested when in multiple channel mode.