UTM-00330
|
Rev 5
Page
26
of
91
DetNet South Africa Copyright © 2019
This function enables the user to assign a position to one detonator at a time.
The position is either a combination of a side (left/right), a row number (1-63), a hole number (1-127) and
detonator number in a decked hole (1-15) OR a Special – an out-of pattern detonator (1-255).
1. Main Menu
Press
to select
Tag Detonators.
2. Tag Detonators Warning
Press
Soft Key to acknowledge warning.
3. Tag Side
Press
Soft Key to tag only on one side.
Press
Soft Key to tag both sides.
4. Tag Side (Cont.)
This screen will not be displayed again unless the memory is cleared via new design
or the tagger is restarted.
Press
Soft Key to tag only on the left-hand side.
Press
Soft Key to tag only on the right-hand side.