![digico D5T Operation Manual Download Page 154](http://html1.mh-extra.com/html/digico/d5t/d5t_operation-manual_2496913154.webp)
B-8
Appendix B
Optical connections should be:
Stage Rack 1 Opto A to Stage Rack 2 Opto B.
Stage Rack 2 Opto A to Redundant Engine Opto B.
Redundant Engine Opto A to Main Console Opto B.
Main Console Opto A back to Stage Rack Opto B if a Redundant Optical Loop is required.
MADI connections with the Local Racks should be:
Main Console MADI 2 OUT to Local Rack MADI A IN.
Main Console MADI 2 IN to Local Rack MADI A OUT.
Redundant Engine MADI 2 OUT to Local Rack MADI B IN.
Redundant Engine MADI 2 IN to Local Rack MADI B OUT.
The Redundant Engine has ports on its rear panel for the supplied
trackball and keyboard
and
a monitor
should be connected to the
expanded VGA output on the rear panel to view the required screen. In normal operation the
Master
screen would be required to fire
Snapshots (Cues) but the Overview screen could also be connected to make fader adjustments etc.
The ideal solution would be to fit a multiple port video switcher that would enable easy access to any of the Input, Master or Overview
screens.
B.2.3 DiGiConfig – Hardware Configuration ..............................
NOTE: The Main console and the Redundant Engine must both be running the same version of software.
When the system is connected and switched on the DiGiConfig Program should be run on all of the devices in the system by pressing the
Configure Hardware
button in the
System/Service
menu.
The example below shows the settings for a system with a Main Front of House console and its Redundant Engine, a Monitor console and
its Redundant Engine and a Remote Controlller or Theatre Controller for the Front of House console.
All the devices should have all of the components of the system selected but the “
THIS ONE?
” button should be selected according to
which device you are setting up.
If you wish to view or customise the settings, press the
Edit Details
button and a panel will open showing all the relevant details.
Unless you are troubleshooting the system, this should not be necessary and you should simply press the
OK
button to return to the
console application itself.
FOH Main Console
FOH Redundant Engine
Summary of Contents for D5T
Page 1: ...Operation Manual Issue A September 2004 Software Versions 2 4...
Page 2: ......
Page 10: ......
Page 11: ...Chapter 1 1 1 Chapter 1 Getting Started...
Page 12: ...Chapter 1 1 2...
Page 32: ...Chapter 2 2 1 Chapter 2 Inputs and Console Channels...
Page 33: ...Chapter 2 2 2...
Page 58: ...Chapter 3 3 1 Chapter 3 Busses and Outputs...
Page 59: ...3 2 Chapter 3...
Page 68: ...4 1 Chapter 4 Chapter 4 Master Section...
Page 69: ...Chapter 4 4 2...
Page 91: ...5 1 Chapter 5 Chapter 5 The Cue List...
Page 92: ...Chapter 5 5 2...
Page 111: ...Chapter 6 6 1 Chapter 6 Automation...
Page 127: ...7 1 Chapter 7 Chapter 7 Effects...
Page 128: ...7 2 Chapter 7...
Page 135: ...8 1 Chapter 8 Chapter 8 Troubleshooting...
Page 136: ...Chapter 8 8 2...
Page 139: ...A 1 AppendixA Appendix A D5TC Theatre Masters Controller...
Page 140: ...A 2 Appendix A...
Page 147: ...B 1 Appendix B Appendix B Multiple Console Setups Inc Redundant Engines...
Page 148: ...B 2 Appendix B...
Page 162: ...B 16 Appendix B Standalone PC Screen Appearance...