159
failover
Configures WAN failover settings.
Syntax
failover <1 - 10> <parameter> <value>
Parameters
state
Enables or disables this WAN failover configuration.
Value is either on or off. The default value is off.
from
The WAN interface to failover from. Also known as the primary WAN interface.
Accepted values can be one of none, lan1, lan2, lan3, lan4, lan5, lan6, lan7, lan8, lan9, lan10, dsl,
cellular1 or cellular2. The default value is none.
to
The interface to failover to. Also known as the backup WAN interface.
Accepted values can be one of none, lan1, lan2, lan3, lan4, lan5, lan6, lan7, lan8, lan9, lan10, dsl,
cellular1 or cellular2. The default value is none.
use
The failover detection method.
Accepted values can be one of ping or passive. The default value is passive.
timeout
The number of seconds after which the primary WAN interface should fail over to the backup WAN
interface.
Accepted value is any integer from 10 to 3600. The default value is 180.
probe-host
The IPv4 device to send probe packets to.
Value should be a fully qualified domain name.
probe-interval
The interval, in seconds, between sending probe packets.
Accepted value is any integer from 1 to 3600. The default value is 60.
probe-size
The size, in bytes, of the probe packet.
Accepted value is any integer from 64 to 1500. The default value is 64.