© DICTATOR Technik GmbH • Gutenbergstr. 9 • 86356 Neusäß • Germany
Tel. +49(0)821-24673-0 • Fax +49(0)821-24673-90 • E-mail [email protected] • 20200430
Page 07.045.17
Technical Manual
DICTAMAT OpenDo
After all desired settings have been made via the potentiometer and the
DIP switches, they must be accepted via the reset button.
IMPORTANT:
If commissioning has not yet been carried out, please
jump to point 7 (page 07.021.18). The settings are also adopted by
the commissioning.
To adopt the settings after commissioning and during operation, the
following steps must be taken:
• Press the reset button for approx. 2 s.
→ LED
starts flashing red continuously. The controller is in
configuration mode.
• If not already done, set the desired configuration. Then press
the reset button for less than 0.5 s. The controller exits the
configuration mode.
→
LED starts flashing red twice in quick succession with a
pause of 1.5 s. The control unit is in start state.
• Now perform a movement in any direction. The door drive moves
in creep speed.
→
The red LED goes out, the configuration has been accepted.
6. Setting the Desired Functions
- cont.
5. This setting refers to the closing speed of the DIP switches 6 - 8. In
position OFF the closing speed is only 50 % of the speed set in 6 - 8.
6. to 8.
The closing speed to be set refers to the weight of the door leaf:
6. Weight of door leaf max. 80 kg
→
20 cm/s
7. Weight of door leaf max. 60 kg
→
23 cm/s
8. Weight of door leaf max. 40 kg
→
25 cm/s
6d) Setting the DIP
Switches
- cont.
6e) Accepting the
Settings