© DICTATOR Technik GmbH • Gutenbergstr. 9 • 86356 Neusäß • Germany
Tel. +49(0)821-24673-0 • Fax +49(0)821-24673-90 • E-mail [email protected] • 20200430
Page 07.045.18
Technical Manual
DICTAMAT OpenDo
To put the DICTAMAT OpenDointo operation a complete reset must be
carried out. This reset also takes over previously configured settings, so
step 6e, "Accepting the settings" is not necessary.
The following steps must be carried out for the reset:
• Connect the controller to the power supply
→
LED starts flashing red twice in quick succession with a
1.5 s pause.
• Press reset button for approx. 2 s.
→ LED
starts flashing red continuously.
• Check direction of rotation. Open with OPEN button or close with
CLOSE button. If the running direction is wrong:
→
Turn motor cable and check direction of rotation again.
For
this purpose the power supply must be disconnected beforehand!
• Move the door leaf to the middle position with the keys. Now
press the reset button again for approx. 2 s.
• The red LED is now permanently lit. The yellow LED lights up
during motor activity.
The drive moves to the end position Open.
The drive moves to end position Closed.
The drive moves to end position Open.
• The LEDs go out, now the desired functions can still be checked. If
these functions work, commissioning is now complete.
7. Commissioning
CAUTION!
Danger from moving door!
The door moves automatically during commissioning.
Please keep the danger area clear during commissioning.