OFF ON
6. Setting the Desired Functions
- cont.
Abb. 16
The DIP switches can be used to configure the operating modes listed
in 6a, among others. Please always make sure to carry out changes in
the de-energized state!
6d) Setting the DIP
Switches
Switch
Description
OFF
ON
1
Function
Semi-
automatic
Automatic
2
Deadman
Deactivated Activated
3
Push & Go
Deactivated Activated
4
Behaviour in
case of obstacle Reversing
Stop
5
Closing speed
50 %
Full
6
Door leaf max.
80 kg
Deactivated Activated
7
Door leaf max.
60 kg
Deactivated Activated
8
Door leaf max.
40 kg
Deactivated Activated
1. In semi-automatic mode, the door operator does not close
automatically. The hold-open time set at potentiometer P1 is ignored.
In automatic mode, the door operator closes after the hold-open
time set at potentiometer P1.
2. In deadman mode the door drive only runs as long as the
operator push-button is pressed.
If DIP switch 2 is set to ON, the position of DIP switch 1 is
ignored!
If DIP switch 2 is set to OFF, the settings of DIP switch 1 apply.
3. When Push & Go is activated, the door drive starts moving auto-
matically as soon as the door is pushed. Only possible in OPEN
direction!
4. If reversing is active, the door drive moves in the opposite
direction if an obstacle is detected during the closing
movement. During the opening movement, the drive stops.
When reversing, the drive always moves at reduced speed.
If DIP switch 4 is set to ON (STOP), the drive stops when an obstacle
is detected, both during opening and closing.
Fig. 16