© DICTATOR Technik GmbH • Gutenbergstr. 9 • 86356 Neusäß • Germany
Tel. +49(0)821-24673-0 • Fax +49(0)821-24673-90 • E-mail [email protected] • 20200430
Page 07.045.15
Technical Manual
DICTAMAT OpenDo
ON
1 2 3 4 5 6 7 8
6. Setting the Desired Functions
- cont.
Fig. 15
6b) Overview
The settings of the OpenDo are made by means of the potentiometer
P1, the DIP switches and the RESET button on the control unit.
The following diagram shows where these components are located on
the controller.
DIP switches
Reset button
LEDs for function
indication
Potentiometer P1
Potentiometer P1
The potentiometer can be used to set the hold-open time of the door
operator.
The following applies:
Turning clockwise
→
Hold-open time is extended
Turning counterclockwise
→
Hold-open time is reduced
IMPORTANT: The potentiometer has a stop in both directions of rotation
which must not be overtightened! The potentiometer must therefore
always be turned with extreme caution and suitable tools! Damage can
lead to malfunctions.
6c) Adjusting the
Potentiometer